background image

 2

IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues

 
 
Limited Warranty: This warranty covers defects or malfunctions in this equipment.  This warranty lasts 
for a period of one year from date of purchase.  It is the owner’s responsibility to provide invoices for 
proof of purchase, purchase date and dealer or distributor.  If purchase date can not be provided, 
warranty period will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace 
parts or equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, 
belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items 
or any problem resulting from the following: improper wiring, incorrect voltage (including low or over 
voltage conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage 
resulting from shipping.  Warranty will be null and void if the product is altered, modified, misused, 
damaged, or subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to 
state.  Any liability for consequential and incidental damages is expressly disclaimed.  No other warranty, 
expressed or implied is made.  Techni-Lux liability in all events is limited to, and shall not exceed, the 
purchase price paid. 
 
Returning equipment and Repairs:  All returns must be accompanied by a Return Merchandise 
Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.  The RMA number must be clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed problem or error encountered.  Techni-Lux is solely responsible for determining a product’s 
eligibility for coverage under warranty.  If returning for consideration of credit, all accessories and 
documentation, original protective material and cartons must be included and the equipment, packing 
and carton must be in new resalable condition. Credit for returned merchandise will be issued at the 
lowest current price and is subject to a restocking fee.  No returns accepted on discontinued items.  
Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any 
return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or 
sent by freight collect.   
 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 
Model Number (circle):  

DL-QUADBOX1630TC 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 
 

www.Techni-Lux.com

 

 
 

Summary of Contents for DL-QUADBOX1630TC

Page 1: ...Information specifically for DL QUADBOX1630TC v1 0 This manual contains important information Please read before operating fixture...

Page 2: ...o and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Page 3: ...eration P01 P15 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 DMX Operation 8 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 9 Adapter 5 to 3 pin 10 DMX Start Address 10 D...

Page 4: ...58 x 14 96 x 6 5 Weight 17 2 lbs 7 8 kgs Housing Material Steel Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated...

Page 5: ...urn Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to sh...

Page 6: ...that allows adjustment and positioning when mounted Mounting holes are provided on each bracket to help accommodate a clamp Always keep cords out of the way thus preventing any trip hazards Secure al...

Page 7: ...nuous loop With the DL OCTOBAR830TC fixture you can select one static color or from 14 different program chases Each program is described in the table below To select a program Press the MODE button t...

Page 8: ...used to connect fixtures together To set this mode press the MODE button to select the SLAVE mode Any devices set in this manner can now be controlled by the master unit Press the ENTER button to con...

Page 9: ...e the same data fixtures may be set to any address without concern for the order they are connected by the DMX cables DMX Data Connection This fixture uses both 3 and 5 pin XLR type connectors and shi...

Page 10: ...ect Start Addresses for 4 fixtures each requiring 5 channels of DMX 5 channel mode For this example start with the first unit set to the first possible Start Address 1 This fixture occupies DMX channe...

Page 11: ...n only with additional Master dimmer strobing and sound control channels Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 C...

Page 12: ...CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 11 CH 12 Function R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 Value 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Channel CH 13 CH 14 CH 15 CH 16 CH...

Page 13: ...25 CH 26 CH 27 CH 28 CH 29 CH 30 CH 31 CH 32 CH 33 CH 34 CH 35 CH 36 Function R7 G7 B7 R8 G8 B8 R9 G9 B9 R10 G10 B10 R11 G11 B11 Value 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255...

Page 14: ...dimmer 64 71 RGB Master dimmer 72 79 Color 1 Master dimmer 80 87 Color 2 Master dimmer 88 95 Color 3 Master dimmer 96 103 Color 4 Master dimmer 104 111 Color 5 Master dimmer 112 119 Color 6 Master dim...

Page 15: ...or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secur...

Page 16: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...