background image

 

15

Maintenance 

Make sure fixture is cool and disconnected from power mains before any service. 

 

 

Weekly operating hours and environmental conditions will establish how often the fixtures need 
cleaning.  Fixtures should be cleaned and inspected at least once a month to maintain optimum 
performance.  Accumulation of dust and fog residue increases heat build up, can lead to 
malfunctions, overheating and reduction in maximum light output, reduced fixture life and over 
all performance.  Before conducting any maintenance, disconnect fixture from power mains.   
  
1) Disconnect fixture from power mains. 
2) Use a vacuum with a soft brush to remove dust collected on external vents, heat sinks and 
internal components.  If using an air compressor, use low pressures and extreme care to 
prevent damaging any internal parts or effects. 
4) Clean all optical elements when the fixture is cold.  Use a soft lint free cotton cloth or tissue 
and cleaner safe for plastics.  
5) Inspect clamps and safety cables to ensure fixture is secure and safe. 
 
 

Accessory Items 

(sold separately)

 

 

Order Code 

Description 

CLAMP-MEGA/B 

Mega Heavy Duty Aluminum Clamp – Black 

CLAMP-CBHALF 

Half Cheeseborough Coupler 300kg Max Load  

 

 

SAFETYCABLE18B 

Safety Cable Black 18” 

SAFETYCABLE18S 

Safety Cable Silver 18” 

 

 

CA-XLR5/5 

Pre-made 5’  5-pin XLR Cable 

CA-XLR5/10 

Pre-made 10’ 5-pin XLR Cable 

CA-XLR5/25 

Pre-made 25’ 5-pin XLR Cable 

 

 

CA-XLR3/5 

Pre-made 5’ 3-pin XLR Cable 

CA-XLR3/10 

Pre-made 10’ 3-pin XLR Cable 

CA-XLR3/25 

Pre-made 25’ 3-pin XLR Cable 

 

 

CO-XLR5M   

XLR Connector 5-pin Male 

CO-XLR5F 

XLR Connector 5-pin Female 

CO-XLR3M   

XLR Connector 3-pin Male 

CO-XLR3F 

XLR Connector 3-pin Female 

 

 

CO-XLRTERM5 

XLR 5 Pin Data Terminator 

CO-XLRTERM3 

XLR 3 Pin Data Terminator 

 

 

CO-XLR3MTO5F 

XLR 3 Pin Male to 5 Pin Female Adapter 

CO-XLR5MTO3F 

XLR 5 Pin Male to 3 Pin Female Adapter 

 

 

Summary of Contents for DL-QUADBOX1630TC

Page 1: ...Information specifically for DL QUADBOX1630TC v1 0 This manual contains important information Please read before operating fixture...

Page 2: ...o and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Page 3: ...eration P01 P15 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 DMX Operation 8 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 9 Adapter 5 to 3 pin 10 DMX Start Address 10 D...

Page 4: ...58 x 14 96 x 6 5 Weight 17 2 lbs 7 8 kgs Housing Material Steel Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated...

Page 5: ...urn Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to sh...

Page 6: ...that allows adjustment and positioning when mounted Mounting holes are provided on each bracket to help accommodate a clamp Always keep cords out of the way thus preventing any trip hazards Secure al...

Page 7: ...nuous loop With the DL OCTOBAR830TC fixture you can select one static color or from 14 different program chases Each program is described in the table below To select a program Press the MODE button t...

Page 8: ...used to connect fixtures together To set this mode press the MODE button to select the SLAVE mode Any devices set in this manner can now be controlled by the master unit Press the ENTER button to con...

Page 9: ...e the same data fixtures may be set to any address without concern for the order they are connected by the DMX cables DMX Data Connection This fixture uses both 3 and 5 pin XLR type connectors and shi...

Page 10: ...ect Start Addresses for 4 fixtures each requiring 5 channels of DMX 5 channel mode For this example start with the first unit set to the first possible Start Address 1 This fixture occupies DMX channe...

Page 11: ...n only with additional Master dimmer strobing and sound control channels Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 C...

Page 12: ...CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 11 CH 12 Function R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 Value 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Channel CH 13 CH 14 CH 15 CH 16 CH...

Page 13: ...25 CH 26 CH 27 CH 28 CH 29 CH 30 CH 31 CH 32 CH 33 CH 34 CH 35 CH 36 Function R7 G7 B7 R8 G8 B8 R9 G9 B9 R10 G10 B10 R11 G11 B11 Value 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255...

Page 14: ...dimmer 64 71 RGB Master dimmer 72 79 Color 1 Master dimmer 80 87 Color 2 Master dimmer 88 95 Color 3 Master dimmer 96 103 Color 4 Master dimmer 104 111 Color 5 Master dimmer 112 119 Color 6 Master dim...

Page 15: ...or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secur...

Page 16: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...