background image

 

11 

140-144 

Color Scroll Snap Speed 12 

145-149 

Color Scroll Snap Speed 13 

150-154 

Color Scroll Snap Speed 14 

155-159 

Color Scroll Snap Speed 15 

160-164 

Color Scroll Snap Speed 16 

165-169 

Color Scroll Snap Speed 17 (Slowest) 

170-174 

Color Scroll FADE Speed 1  (Fastest) 

175-179 

Color Scroll FADE Speed 2 

180-184 

Color Scroll FADE Speed 3 

185-189 

Color Scroll FADE Speed 4 

190-194 

Color Scroll FADE Speed 5 

195-199 

Color Scroll FADE Speed 6 

200-204 

Color Scroll FADE Speed 7 

205-209 

Color Scroll FADE Speed 8 

210-214 

Color Scroll FADE Speed 9 

215-219 

Color Scroll FADE Speed 10 

220-224 

Color Scroll FADE Speed 11 

225-229 

Color Scroll FADE Speed 12 

230-234 

Color Scroll FADE Speed 13 

235-239 

Color Scroll FADE Speed 14 

240-244 

Color Scroll FADE Speed 15 

245-249 

Color Scroll FADE Speed 16 

250-255 

Color Scroll FADE Speed 17 (Slowest) 

 
 

CH 6   : Shutter 

The Shutter functions  in all modes.  The shutter effect will toggle the Master Level 
between Off and its present value. 
 

CH 15 – Shutter 

DMX Value 

Function 

0-4 

No Strobe 

5-255 

Strobe Effect - Slow to Fast 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DL-PAR64C183/B

Page 1: ...Information specifically for DL PAR64C183 B Black DL PAR64C183 P Polished V1 This manual contains important information Please read before operating fixture ...

Page 2: ...hall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanied by a writ...

Page 3: ...d 7 Mode 3 Color Fade 7 Mode 4 Sound Active 7 Mode 5 Slave 7 Mode 6 DMX 7 DMX 512 Control 8 DMX Data Connection 8 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignment 9 CH 1 Master Dimmer 9 CH 2 Red 9 CH 3 Green 10 CH 4 Blue 10 CH 5 Color Macro Scroll 10 CH 6 Shutter 11 Maintenance 12 Accessory Items sold separately 12 Troubleshooting 13 DMX 512 Background 13 ...

Page 4: ...isplay menu for settings Dual yoke for floor or hang mounting Clamp mounting hole Physical Color Black or Polished Size 13 x 11 25 x 10 6 Weight 5 1 lbs 2 3 kg Housing Material Aluminum Environmental Location Indoor Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage 110 240vAC 50 60Hz Rated Power 30W Fuses 0...

Page 5: ...of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cartons Power Do not apply power to the fixture until power source is verified For protection against electric shock fixture must be connected to suitable earth ground Make sure fixture is ...

Page 6: ...different modes that are available on this fixture via the LED display Each mode is selectable from the display menu located at the back of the fixture Modes 1 to 5 refer to the stand alone operations that are available Modes 1 4 do not require any data line to be connected to the fixture to function However Mode 5 and Mode 6 require data cables to be used Mode 6 refers to the DMX controlled opera...

Page 7: ...r to the next and at different speeds F300 RGB fades through RGB at a speed set from 00 99 F700 7 COLOR fades through 7 standard colors at a speed from 00 99 FF00 STROBE sets the flashing speed from 00 99 Mode 4 Sound Active Display shows S000 Mode 4 uses the internal microphone to advance through the selected option from below By listening to ambient music the fixture will make changes at audio p...

Page 8: ...the first light then from the DMX OUT to the DMX IN of the next light and so on Only one data source can be on a chain and no branching is allowed The physical order in which the fixtures are connected is not important use the most convenient Data Terminator A Data Terminator can be connected to the DMX OUT of the last fixture to reduce the effects of signal noise it is not required for all instal...

Page 9: ...e will leave no empty channels between fixtures so the second Start Address is set to DMX channel 7 and that fixture occupies channels 7 thru 12 The third fixture will be addressed 7 6 13 and occupy channels 13 thru 18 The last fixture is addressed 13 6 19 and will occupy channels 19 thru 24 Thus 4 fixtures using 6 channels each have Start Addresses of 1 7 13 and 19 and the next free channel in th...

Page 10: ...lor Macro Scroll DMX Value Function 0 4 No Macro or Scroll 5 9 Cool White 10 14 Lt Blue 15 19 Blue 20 24 Purple 25 29 Blue Magenta 30 34 Magenta 35 39 Hot Pink 40 44 Pink 45 49 Red 50 54 Orange 55 59 Yellow 60 64 Lime 65 69 Lt Green 70 74 Green 75 79 Teal 80 84 Cyan 85 89 Color Scroll Snap Speed 1 Fastest 90 94 Color Scroll Snap Speed 2 95 99 Color Scroll Snap Speed 3 100 104 Color Scroll Snap Spe...

Page 11: ...roll FADE Speed 6 200 204 Color Scroll FADE Speed 7 205 209 Color Scroll FADE Speed 8 210 214 Color Scroll FADE Speed 9 215 219 Color Scroll FADE Speed 10 220 224 Color Scroll FADE Speed 11 225 229 Color Scroll FADE Speed 12 230 234 Color Scroll FADE Speed 13 235 239 Color Scroll FADE Speed 14 240 244 Color Scroll FADE Speed 15 245 249 Color Scroll FADE Speed 16 250 255 Color Scroll FADE Speed 17 ...

Page 12: ... the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP C Medium Duty C Clamp CLAMP MEGA B Mega Heavy Duty Aluminum Clamp CLAMP MINI P Mini Clamp Polished for 3 4 2 CLAMP MINI B Mini Clamp Black for 3 4 2 CLAMP CBHALF N Half Che...

Page 13: ...smitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration cal...

Reviews: