AIMA3000.FT5P Product User Manual
Technetix Group Limited
•
technetix.com
May/2016 - Version 1.0
34
6.1.1 Confirming Input Signal
Input Signal is shown as the red box in Figure 6-3:
Input Power Calculations
The relationship between input power and the number of channels:
Per channel Power = Input Power -10*LOG (number of channels)
On Figure 6-3, the interface displays the
“Broadcast Input Power”/“Narrowcast Input Power”
and the
"RF Composite
Input Power"
. The operator can calculate the power per channel. When the different channels and levels are configured
for the FT5P, the operator can also calculate the appropriate gain adjustment to ensure the total RF power for the laser.
All alarm information is monitored by the ASMM module. If an alarm occurs, the operator can view the associated module
page to find more detailed alarm information.
Figure 6-3