AIMA3000.FT5P Product User Manual
Technetix Group Limited
•
technetix.com
May/2016 - Version 1.0
29
FT5P Initial Setup
1.
Pending finalisation of module.
2. Before installing the FT5P, check the optical output ferrule tip with a fibrescope to ensure that the connector is
clean (pictured below). The cap on the optical output connector does not prevent contamination from getting
on to the optical connector, it prevents the laser from being emitted when laser is on and no optical patch
cord is installed.
3. Next install the FT5P unit into a slot where RF input leads are connected and check the optical output power
with a cleaned optical patch cord and a calibrated optical power meter. Record the optical output level. Connect
a cleaned patch cord to the fibre output and to the relevant optical distribution frame (ODF) panel.
4. With a laptop connected to the ASMM module’s network or an Android device connected to the front of the ASMM .
module’s USB port in host mode. Select the port for the transmitter that needs to be adjusted, confirm that the
“Input
AGC mode”
is set to
“OFF”
, if not change it to
“OFF”
and then click on
“Submit”
button. In addition, confirm that the
“Broadcast MGC”
and
“Narrowcast MGC”
is set to 0.0, if not set to
"0.0"
and click on
“Submit”
button.
5. Confirm in the management
“Status”
section that the broadcast and narrowcast input power levels and the RF
Composite Input Power are within the designated parameters.