ADDItIonAL   InFoRMAtIon

Brief fault finding notes and lists of accessories are given in this 
section.
NOTE THAT THIS EQUIPMENT SHOULD ONLY BE DISMANTLED 
BY PROPERLY TRAINED PERSONNEL. 

ReMovInG the oUteR CoveRs oR BAse exPoses 

PotentIALLy LethAL MAIns voLtAGes AnD A FAn.

THERE ARE NO USER SERVIcEABLE PARTS WITHIN THE 
EQUIPMENT.

General advice

In the unlikely event that you experience any problems with your 
refrigerated unit which cannot be easily remedied, you should 
contact your supplier and return the unit if necessary. Please 
include any details of the fault observed and remember to return 
the unit in its original packing. Techne accept no responsibility for 
damage to units which are not properly packed for shipping: if in 
doubt, contact your supplier.

Fuses

If the power light on the power switch is lit, the fuse may have 
blown. Make sure there is no external cause (such as a faulty plug 
or lead).
Fuses should only be changed by suitably qualified personnel.  If 
the fuses blow persistently, a serious fault is indicated and you 
may need to return the unit to your supplier for repair.
Replacement fuse numbers are as follows, and can be ordered 
from Techne or thier agents;

 Number   

Rating 

Unit voltage

 RB-5A
 6008444       T4A        4 amp time delay 

230V

 6501239       T8A        8 amp time delay 

120V

 RB-12A or RB-22A
 6008442       T8A        4 amp time delay 

230V

 6008443       T12.5A   8 amp time delay 

120V

Accessories

There are many accessories, these are constantly being updated 
and details can be found in Techne Sales literature.  They include: 
 

Temperature Program Software;

 

cooling Water Pack;

 

Refrigeration control Pack;

 

Test Tube Racks;

 

and so on.

Summary of Contents for RB-12A

Page 1: ...P A G E 1 R e f r i g e r a t e d B a t h s U S E R S M A N U A L RB 5A RB 12A RB 22A Refrigerated Baths OPERATOR S MANUAL Issue 12 Date of issue 22nd March 2011 Techne is a trademark Techne 2012...

Page 2: ......

Page 3: ...ais 5 Deutsch 6 Espa ol 7 Introduction 8 Operator Safety 8 Specification 9 Siting Considerations 10 Setting up the unit 10 Cleaning your unit 12 Packing 12 Operation 13 Precautionary Measures 13 Oper...

Page 4: ...ing meanings I mains switch On O mains switch Off After use When you have finished heating samples remember that partsoftheunit thetubes blocksandassociatedaccessories may be very hot Take the precaut...

Page 5: ...reil sur un plan de travail ou surface plane ou le cas ch ant dans une hotte d aspiration en s assurant que les trous d a ration situ s sous l appareil ne sont pas obstru s 5 Les symboles situ s sur o...

Page 6: ...e Arbeitsfl che bzw falls erforderlich unter einen Laborabzug Beachten Sie da die Entl ftungsrippen an der Ger teunterseite immer frei zug nglich sind 5 Die Symbole auf oder neben dem EIN AUS Schalter...

Page 7: ...elasentradasdeaireenlaparteinferiornoqueden obstruidas 5 Loss mbolosqueseencuentranenocercadelinterruptor de alimentaci n tienen los siguientes significados I Interruptorprincipalencendido O Interrupt...

Page 8: ...lator TE 10 series or TU 20 series Each unit fridge or controller has its particular application which should be considered when setting up a temperature controlled system The refrigerated baths have...

Page 9: ...lation system condition of the working liquid heat input and so on RB 5A RB 12A RB 22A Minimum temperature 20 o C 35 C 30 C Cooling capacity at 20 o C 145 W 240W 240W 0 o C 145 W 240W 240W 10 o C 110...

Page 10: ...at of the mains supply Connect the mains cable to a suitable plug as in the following table Note that the unit must be earthed to ensure proper electrical safety Connections 230V 110 120V Live brown b...

Page 11: ...hich will cover the full range of working temperatures The RB 12A RB 22A units are designed to work up to 40o C with occasional peaks to 100o C The RB 5A can be used up to 150 C but unit should be tur...

Page 12: ...following have been removed from the packing a power cable RB 5A only a decontamination certificate and a Guarantee Card Check that the unit is the correct rating for your power supply by looking on t...

Page 13: ...temperatures below 40o C 5 IN NO CIRCUMSTANCES MAY A REFRIGERATED UNIT BE SUBJECTED TO BATH LIQUID TEMPERATURES ABOVE 100o C Operating your unit 1 Switch on the thermoregulator as instructed in the a...

Page 14: ...ter or by balls from a ball blanket or in any other way Also check that the pipe system if you are using the fridge unit for an external system is not kinked or restricted in any way 4 If the liquid o...

Page 15: ...as to the gas charge for each of the units Unit Refrigerant Charge RB 5A R134a 85 gm RB 12A R404a 250 gm RB 22A R404a 250 gm There have been several improvements in design which have varied the charg...

Page 16: ...ge to units which are not properly packed for shipping if in doubt contact your supplier Fuses If the power light on the power switch is lit the fuse may have blown Make sure there is no external caus...

Page 17: ...P A G E 17 R e f r i g e r a t e d B a t h s U S E R S M A N U A L...

Page 18: ...P A G E 18 R e f r i g e r a t e d B a t h s U S E R S M A N U A L...

Page 19: ...g the details below UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 330 088 0560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specific...

Reviews: