![TechGrow Ballast Basic Micro User Manual Download Page 16](http://html1.mh-extra.com/html/techgrow/ballast-basic-micro/ballast-basic-micro_user-manual_1066465016.webp)
____________________________________________________________________________________________________________________________
Tech
Grow
| Innovative Growing Solutions
16
Set the desired switching times. Depending on the
selected time clock the on/off times are displayed with
+ /
–
(24 hour) or arrows (asymmetric timer).
Press the PTK to return to the main screen.
5.4 Set startup delay
You are in the
main menu. Select “Startup delay”.
Adjust the amount of minutes (up to 300 minutes) and
press the PTK or wait a few seconds to return to the
main screen.
5.5 Temperature settings
On the Ballast Connect Micro you can set the "normal"
and "overheat" temperature, provided that a Temp
Probe (not supplied) is connected to the Ballast
Connect Micro.
ATTENTION: Before connecting the Temp Probe you
must first switch off the Ballast Connect Micro via
the "maintenance mode" (see section 5.8). Then
disconnect the Ballast Connect Micro from the
socket. Plug the Temp Probe into the Ballast
Connect Micro and reconnect the Ballast Connect
Micro to the socket.
You are in the main menu. Select “Temperature”.
Set the values for “normal” en “overheat”.
Press the PTK to return to the main screen.
A notification is displayed during an over-temperature
situation.
O
At "Overheat T" one lamp will be turned off. The red
LED goes off. This can be a random lamp, but there is
also the option to always switch off relay L2. In this case
L1 (lamp 1) remains switched on, even during an over-
temperature situation.
To adjust L1 to remain switched on, select "Keep lamp
On" in the main menu under "Settings".
As soon as the temperature falls under "Normal temp"
the lamp will be turned on again.
No lamp will be switched between "Normal temp" and
"Overheat T".
5.6 LCD on-time
You are in the main menu. Select "Settings" and then
"LCD on-time".
Select the desired number of seconds and confirm by
pressing the DDK.
LCD on-time 200s
=> Keep lamp On
=> LCD on-time 200s
Keep lamp On
Timer mode
=> Set timers
On at 00:00
Off at 00:00
Set timers
=> Startup delay
Startup delay:
.. minutes
Startup delay
=> Temperature
Normal °C
28.0
Overheat 32.0
34.2 °C 10:57:28
Overheat!