15
Installation positions
•
Volume measuring section: ≤ 45° rotated in relation to the horizontal axis.
•
The casing must not be installed facing upwards or downwards.
•
Only install the computer unit vertically, slanting or horizontally.
•
Always insert the sensor cable from below.
Notes on installing temperature sensors
•
To correctly capture small temperature differences, the temperature sensor should be
installed directly dipped (i.e. without the immersion pocket) – this is prescribed up to DN
25 for new cold meter installations and is mandatory. The sensor can also be installed for
the DN 40 in a special ball valve with special sensors.
•
Install temperature sensors at locations with the same and higher flow speed.
•
To reduce measurement differences caused by installation, use a diffusion resistant
insulation. Design the isolation so that no condensate can penetrate into the insulation
of the pipeline via the temperature sensor.
Displays/operation
It is possible to flip through the individual displays by pressing the push-button. In doing
so, we distinguish between pressing the button briefly and longer pressing.
A
brief
press of the button (
< 3
seconds) is switched within a loop.
If you press the button
longer
(
> 3
seconds) it switches to the next loop.
Error codes
If an error occurs, the error code is shown in the main loop. All the other windows remain
available via pressing the button.
Code Description
C-1
Fundamental parameter destroyed in flash memory or RAM
E-1
Faulty temperature measurement:
- Temperature range outside (-19.9 °C...189.9°C)
- Sensor short circuit
- sensor break
E-3
Sensors in hot and cold branches interchanged
E-4
Hardware error during ultrasonic measurement:
- Ultrasonic converter faulty
- Ultrasonic converter short circuit
E-5
Readout too frequent - optical communication momentarily not possible
E-6
Wrong flow direction
- flow rate sensor incorrectly installed
E-7
No meaningful ultrasonic receiving signal:
- Air in the measuring section
E-8
Primary power supply failed (only for power supply units)
- supply via a backup battery
Summary of Contents for ultra S3
Page 84: ...84 16 4 4 EN 1434 Plug Play M Bus 250mm 5 55 C IP 54 93 max 10m 2m 10m...
Page 85: ...85 11 A B OK C OK D OK E OK F OK G OK 50 cm 10 x DN 45 90 45...
Page 86: ...86 15 C 90 C 1 2 3 Pt 500 300mm 1 2 3 O O 4 5 6 7 8...
Page 87: ...87 1 2 3 4 5 6 ultra S3 PTB E IP 65 45 DN25 DN 40...
Page 88: ...88 3 3 C 1 Flash RAM E 1 19 9 C 189 9 C E 3 E 4 E 5 E 6 E 7 E 8 E 9...
Page 94: ...94 16 4 4 1434 Plug Play M Bus RS 232 RS 485 250 5 55 C IP 54 93 10 2 10...
Page 95: ...95 11 A B C D E F G 50 10 45 90 45...
Page 96: ...96 15 C 90 C 1 2 3 Pt 500 300 1 2 3 4 5 6 7 8...
Page 97: ...97 1 2 3 4 5 6 ultra S3 IP 65 45 25 40...
Page 98: ...98 3 3 C 1 RAM flash E 1 19 9 189 9 C E 3 E 4 E 5 E 6 E 7 E 8 E 9...
Page 102: ...102 E1 M1 PT500 1 DE 07 MI004 47114711 PN PS qi 3 qi qp 1 50 CE M qp 3 DN15 qs 3 Q K Q Qq C...
Page 157: ...157...
Page 158: ...158...
Page 159: ...Konformit tserkl rung...
Page 160: ......
Page 161: ......
Page 165: ......
Page 166: ......
Page 167: ......