This installation, apart from the accumulation tank, also has a heat receiver (e.g. a swimming
pool or a CH installation), the task of which is to release rather than collect thermal energy.
Additional Parameters to be Adjusted:
Valve hysteresis.
The set temperature of tank 2.
The maximum temperature of tank 2.
Hysteresis of tank 2.
Oscillation charging.
The oscillation pause time.
The maximum heating time Z2.
Tank reheating priority.
V.a.10)
Scheme 10/17
–
Double Function Furnace
Installation 10/17 Operates:
The Collector Pump.
The valve switching to the two-state reheating furnace.
The Accumulation Tank with top and bottom circulation.
The double function furnace (reheating the output from
the Controller).
One direction of the collectors' location.
Additional peripherals.
Installation Sensors:
The collector's sensor.
The two sensors of the Accumulation Tank – top and
bottom.
This installation works with a double function furnace which
reheats the circulation. If the tank's temperature is too low, the valve switches to the furnace.
Additional Parameters to be Adjusted (additional submenu in the service menu):
Installation's Options: reheating deactivation.
V.a.11)
Scheme 11/17
–
Reheating the CH Return
Installation 11/17 Operates:
The Collector Pump.
The switching valve between the direct flow to the boiler
and flow through the tank.
The Accumulation Tank with top and bottom circulation.
The boiler's return circulation.
One direction of the collectors' location.
Additional peripherals (not possible to cool down via use
of the DHW Pump).
Installation Sensors:
The collector's sensor.
The two sensors of the Accumulation Tank - top and
bottom.
The boiler's return sensor.
This installation is equipped with a valve which, in the case of excess hot water in the tank, switches
the circulation to the boiler's return circulation in order to reheat it ( as well as release the excessive
heat) which will result in solid fuel savings.
Additional Parameters to be Adjusted (additional submenu in the service menu):
Installation's options: energy release threshold, release hysteresis, activation delta,
deactivation delta.