10 Propus Technical specification
Capacity
6KVA
8KVA 10KVA 12KVA 15KVA 20KVA 25KVA 30KVA
AC input
Voltage
380VAC
±
20%
Frequency
50 (60)Hz±5%
Phase
Three Grounding
Max.current
10A
13A
16A
20A
24A
32A
40A
56A
AC output
Voltage
220V
Frequency
50 (60)Hz
Voltage
stability
±1%
frequency
stability
±0.5% (When disconnection)
Wave form
SPWM sine wave
Power factor
0.8 Later
distortion
<3% (linear load)
Battery
Voltage
192VDC
240VDC
Model
Lead –acid free maintenance
Charging time
90% capacity after 8-10 hours
Alarm
Utility disconnect
Buzzer beeps once every four seconds
Battery exhausted
Buzzer beeps once every one second
Overload
Overload indicator light is solid on, buzzer continuously beeps for
long-time.
UPS abnormal
Fault indicator light is solid on, buzzer continuously beeps for long-time.