WIRELESS CONTROLLER RECEIVER
The EU-T-3.2 regulator communicates with the heating device (or the CH boiler controller) by means of a radio signal
sent to the receiver. Such a receiver is connected to the heating device (or the CH boiler controller) by means of a two-
core cable, and communicates with the room regulator using a radio signal.
The receiver has three control lights:
• red control light 1 – signalises data reception;
• red control light 2 – indicates receiver operation;
• red control light 3 – goes on when the room temperature fails to reach the pre-set value – the heating device is switched
on.
NOTE
In case of no communication (e.g. due to discharged battery), the receiver automatically disables the
heating device after 15 minutes.
V.
FIRST START-UP
In order for the EU-T-3.2 controller to work properly, it is necessary to follow these steps when starting the device for the
first time:
1.
Insert the batteries - in order to to do it, remove the front cover of the controller.
2.
Connect the controller to the heating device.
3.
If the room regulator will be used to operate the floor heating system, connect an additional sensor to the floor sensor
connector.
communication button
red control light 1
red control light 2
red control light 3