VI.
HOW TO USE THE CONTROLLER
1.
PRINCIPLE OF OPERATION
The EU-T-3.2 room regulator is designed to maintain the pre-set room temperature by sending a signal to the heating
device or the main controller when the pre- set room temperature has been reached. After receiving such a signal, the
heating device turns off.
NOTE
For the floor heating functions to be available, the floor sensor must be enabled in the controller menu.
2.
OPERATION MODES
The room regulator may operate in one of the following operation modes:
Day/night mode – In this mode the pre-set temperature value depends on the current time of the day. The user
may set different temperature values for the daytime and nighttime as well as define the exact time of entering
day mode and night mode. In order to activate this mode, press MENU button until one of the mode icons
appears on the main screen. The user may define the pre-set temperature and (after tapping on MENU
again) the time of entering day and night mode.
Manual mode
In this mode, the pre-set temperature is adjusted manually from the main screen view
with the use of these buttons:
. Manual mode is activated after pressing MENU button. Once the manual
mode has been activated, the previous operation mode enters ‘’sleep mode’’ until the next pre-programmed
temperature change. Manual mode may be deactivated by pressing EXIT button.
VII.
DEVICE DESCRIPTION
The user operates the device using touch buttons.