background image

 

18 

 

 

 

 

EU Declaration of Conformity

  

 

Hereby, we declare under our sole responsibility that EU-281c

 

manufactured by TECH, head-quartered 

in  Wieprz  Biała  Droga  31,  34-122  Wieprz,  is  compliant  with  Directive  2014/35/EU  of  the  European 
Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of Member States 
relating to the making available on the market of electrical equipment designed for use within certain 
voltage limits
 (EU OJ L 96, of 29.03.2014, p. 357), Directive 2014/30/EU of the European Parliament 
and of the Council of 26 February 2014 on the harmonisation of the laws of Member States relating to 
electromagnetic compatibility
 (EU OJ L 96 of 29.03.2014, p.79), Directive 2009/125/EC establishing a 
framework  for  the  setting  of  ecodesign  requirements  for  energy-related  products  as  well  as  the 
regulation by the MINISTRY OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the 
regulation  concerning  the  essential  requirements  as  regards  the  restriction  of  the  use  of  certain 
hazardous substances in electrical and electronic equipment, implementing provisions of Directive (EU) 
2017/2102 of the European Parliament and of the Council of 15 November 2017 amending Directive 
2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic 
equipment (OJ L 305, 21.11.2017, p. 8). 
 
 

For compliance assessment, harmonized standards were used: 

 PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10. 

 

 

 

Wieprz, 13.06.2022 

 

 

 

 

 

 

 

Summary of Contents for EU-281C

Page 1: ...1 EU 281C...

Page 2: ...ation screen 7 B Main screen description panel screen 9 VI Controller functions menu options 11 1 Block diagram of main menu 11 2 Time 12 3 Protections 13 4 Screen 14 5 Weekly control 14 6 CH boiler c...

Page 3: ...vice may be damaged if struck by a lightning Make sure the plug is disconnected from the power supply during storm Any use other than specified by the manufacturer is forbidden Before and during the h...

Page 4: ...igniter and installation controllers A large clear graphic display with a backlit touch screen makes it easy to read and change the controller parameters EU 281C room regulator offers Room temperature...

Page 5: ...sh mounted The controller should be installed by a qualified person WARNING Risk of fatal electric shock from touching live connections Before working on the controller switch off the power supply and...

Page 6: ...st digit 2 Hold the button and wait until the control light flashes goes on and off the numer of times indicating the first digit of the channel number 3 Release the button When the control light goes...

Page 7: ...REEN DESCRIPTION The controller is equipped with a large touch screen It displays the current status of basic CH boiler parameters Depending on the user s preferences the display may show the heating...

Page 8: ...tor screen displays 8 Water tank 1 temperature current and pre set value tap here to edit the pre set water tank temperature 9 Circulating pump icon animated icon indicates that the pump is active 10...

Page 9: ...nsor is used in the main controller 5 Current room temperature 6 Current time and day of the week 7 Right parameter panel 8 Buttons used to change the screen view 9 Enter the controller menu 10 Left p...

Page 10: ...gulator Chart panel Current temperature chart CH boiler water tank or room temperature graphic representation of temperature changes over time Pellet boiler operation mode panel It offers fire up and...

Page 11: ...Menu Time Clock Day of the week Alarm clock Protections Auto lock PIN code Screen Screensaver Screen view Night from Day from Daytime screen brightness Nighttime screen brightness Weekly control ON OF...

Page 12: ...s used to set the current time according to which the regulator operates Day of the week This function is used to set the current day of the week according to which the regulator operates Alarm clock...

Page 13: ...eds to select the days of alarm clock activation Screen view when the alarm clock is about to be activated 3 PROTECTIONS Tap on Protection icon in the main menu to configure parental lock settings Aut...

Page 14: ...to define the time after which the screensaver is activated Screen view Tap on Screen view icon to adjust the main screen view Installation view is set as default but the user may also select panel s...

Page 15: ...on this icon to change the pre set CH boiler temperature it may also be done by tapping on parameters panel in the main screen view Operation modes Tap on this icon to choose one of the following pum...

Page 16: ...sired oscillation in case of small temperature fluctuation within the range 0 10 C with the accuracy of 0 1 C Example if the pre set temperature is 23 C and the hysteresis is 1 C the room temperature...

Page 17: ...y shows the same message as the main controller If the internal sensor is damaged the following alarm appears Room temperature sensor damaged VIII TECHNICAL DATA Power supply 230V Power consumption 1W...

Page 18: ...agnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the regulation by th...

Page 19: ...19...

Page 20: ...20...

Reviews: