4. ADAPTATION TO DIFFERENT TYPES OF GAS
In the case of operation with other types of gas the burner nozzles must be
changed and the minimum flame adjusted on the gas taps.
To change the nozzles, proceed as described below.
4.1 Replacement of nozzles on the hob
This operation does not require the primary air to be adjusted.
Extract the grids and remove all the caps and flame-spreader crowns;
Unscrew the burner nozzles with a 7 mm socket wrench;
Replace the nozzles according to t he type of gas to be used and the description in paragraph "4.2
Burner and nozzle characteristics table";
Replace the burners in the correct position.
12
Instructions for the installer
Before performing any operations requiring access to powered parts, switch off the power supply
to the appliance.