4. PROGRAMMING OPERATIONS
EO1-11149
4.23 Tare Table Setting (Submode 56)
4-32
4.23 Tare Table Setting (Submode 56)
In 4.7 PLU Table Programming (Submode 4), some of Scale-compulsory PLUs may be set with a
Tare Table Number. The actual Tare Weight is set to each Tare Table here.
Anytime outside a sale
Control
Lock:
SET
56
[#/NS] |Tare
Table
No.|
[#/NS] |Tare
Weight|
[AT/TL]
[#/NS]
NOTE: In the lowest digit of the Tare Weight (gram), only the value “0” or “5” can be set.
Example) To set Tare Table No. 1 with Tare Weight 0.13 LB:
Key Operation: Control Lock: SET, Enter 56 and depress the [#/NS] key.
[1] [#/NS]
(Tare Table No. 1)
[1]
[3]
[AT/TL] (Tare
Weight)
[#/NS]
(To complete this submode.)
4.24 General Unit Weight Setting (Submode 57)
General Unit Weight can be set here so that the Unit Weight may be effective to scale items entered
through departments or PLUs without any individual Unit Weight designation.
Anytime outside a sale
Control
Lock:
SET
57
[#/NS]
|General Unit Weight Code| [AT/TL]
[#/NS]
OPERATION
CONDITION
35*
35*
70
1 digit (1 to 9)
X to 999X (gram) or 0 to 999 (LB)
(Unit: 1/100 LB or gram
Example: Enter 13 for 0.13 LB.)
Repeat for another table.
OPERATION
CONDITION
35*
35*
70
1 to 11
(Refer to General Unit Weight Code Table below.)
Example) To set General Unit Weight Code 2:
Key Operation:
Control Lock: SET,
Enter 57 and depress the [#/NS] key.
[2]
[AT/TL]
[#/NS]
General Unit Weight Code Table
Code
LB unit
Kg unit
1 1
LB 1
Kg
2 2
LB 2
Kg
3 3
LB 3
Kg
4 4
LB 4
Kg
5 5
LB 5
Kg
6 6
LB 6
Kg
7 7
LB 7
Kg
8 8
LB 8
Kg
9 9
LB 9
Kg
10
1/2 LB
100 g
11 1/4
LB ---
Summary of Contents for MA-1535-2 series
Page 1: ...TEC Electronic Cash Register MA 1535 2 SERIES Owner s Manual...
Page 5: ...1 OPERATOR S GUIDE...
Page 6: ......
Page 75: ...2 MANAGER S GUIDE...
Page 150: ...E PRINTED IN MALAYSIA EO1 11149A...