background image

6

TEC-61157-1 Installation Manual-700/710 USB

Pin #5. 

"

Stop signal control

"

. Used if there is no information in CAN bus 

about brake pedal state (check Integrator). Input #5 connect to the 

end switch of the brake pedal. 

Pin #6, 14.

 Data bus CAN-L, CAN-H. Connects to the CAN bus of the 

vehicle (check Integrator).

Pin #7. 

"

Engine lock

"

. Connects to the relay that is used to prevent the 

engine from launching. 

Pin #8.

 

"

Ground

"

. Connects to the vehicles body in the area determined 

by vehicle manufacturer for OEM connection.

Pin #11.

 

"

Turn signals alternate control

"

. Used to

control hazard lights in vehicles where CAN bus is not avaliable. For list

of vehicles that require this connection please refer to Integrato

Pin #13.

 

"

Hood state control

"

. Used if CANBus contains no information 

about hood state.

Pin #15.

 

"

Siren control / Horn control

"

. Required algorithm

is set when installing the Alarm .

Pin #16.

  

"

Power

"

. It is connected through 3A fuse to

any non-sw12V circuit.

CAN bus parameters indication

Geature shown following parameters:

• 

Hood, trunk, doors (each door individually)

• 

Ignition switch state (key presence, АСС, IGN, Start)

• 

Engine is running

• 

Gearbox state (for automatic – P, R, N, D; for manual – R)

• 

Parking brake

• 

Stop-signal

• 

Security

• 

Factory security system alert

• 

Central lock state

• 

Sensors ignore

• 

Engine RPM

• 

Engine temperature

Feature  allow  quickly  check  vehicle state  and  adjust connection 

if required. Buit-ib LED is used for indication (check 

"

Connection 

scheme

"

). LED lights up if any parameter is selected and stays for 5 

seconds or until other parameter is chosen. 

 

"

Engine  RPM

"

  and 

"

Engine  temperature

"

  will  be  indicated if no 

other parameters are chosen:

"

Engine RPM

"

 

— LED flashes with frequency proportional to the RPM: 

1 flash per second equals 500 RPM of the engine. 

"

Engine temperature

"

 

— LED flashes 1 time every time new data 

received (with ignition or or the engine running).

Summary of Contents for 710

Page 1: ...700 710 Installation Manual Hidden Auto Security...

Page 2: ...ation 3 Alarm will be disarmed Warning about open door If you left an open door hood or trunk and armed the Alarm the system will warn you with 3 audible signals LED will inform you about open compart...

Page 3: ...speed control is enabled and supported by the vehicle The engine will be turned off within 5 seconds after the ignition has been turned on if the Speed control is disabled or is not supported by the...

Page 4: ...ion 4 If you made a mistake wait at least 3 seconds and repeat PUK code 5 After succesful entry of the PUK code you may enter new PIN code Maintenance mode In this mode all antitheft and security feat...

Page 5: ...d 150 4 pin 1 Red white Sensor power 12 V 2 Black yellow Sensor power Ground 3 Gray Blue Input Multiplex input 1 Factory default Sensor trigger input 4 Gray Green Input Multiplex input 2 Factory defau...

Page 6: ...algorithm is set when installing the Alarm Pin 16 Power It is connected through 3A fuse to any non switched 12V circuit CAN bus parameters indication Geature shown following parameters Hood trunk doo...

Page 7: ...ative button Analog buttons Digital discreet buttons Maximum current through normally open relay is limited by cross section of the wire 0 35 mm2 When transmitting impulse up to 1 A When receiving up...

Page 8: ...odel will be saved If the vehicle was identified incorrectly press the Programming button twice Repeat programming starting from step 4 Analog steering wheel buttons programming To program analog stee...

Page 9: ...ose hood lock 8 Output 8 4 Impulse after authentication 9 16 pin Input 5 1 Stop signal control 1 10 Functions of programmable inputs 10 Input 13 2 Hood position state 11 8 pin Input 1 7 Alert delay if...

Page 10: ...d 21 Hand brake Emitting a constant level signal when parking brake is enabled 22 External lights Emitting a constant level signal when external lights are on 23 Timer channel Comfort Timer control ch...

Page 11: ...when navigating menu options the first option follows the last one Exiting the programming mode The Alarm will exit programming mode and save all configuration settings in energy independent memory wh...

Page 12: ...ase remember that from the last function the program will go to the first one 7 Release brake pedal Now you can move to programming the next function or exit the programming mode 8 Go to configuring a...

Page 13: ...and PIN code and all other programming options are returned to factory set values To reset to the factory default settings if the Alarm is installed 1 Disconnect power supply from the Alarm 2 Press a...

Page 14: ...nstallation Manual 700 710 USB Use the picture to draw arrangement of the Alarm units This can help to find the alarm units Arranging the Alarm units in the vehicle Keep this sketch out of the reach o...

Page 15: ...card 1 User manual 1 Warranty certificate 1 Connection diagram 1 Unit package 1 Specifications and operating conditions Parameter Value Power supply voltage V 9 15 Maximum current draw in standby mod...

Page 16: ......

Reviews: