We recommend the use of twin(double) wall or twin(double) wall insulated system for
chimney connection.
•
In the interior spaces, by using twin wall chimney system, exhaust gas can be throughed
out to the outside, at the same time fresh air provided to inside. Twin insulated chimney
should be used on the outside.
•
In the interior spaces, by using twin wall insulated chimney system, exhaust gas can be
throughed out to the outside. In this case, you can provıde fresh air by additional pipe
and elbow.
•
To provide fresh air easily, a vent should be used on the nearest window where stove is
installed.
•
Chimney or twin wall insulated chimney, should be at least 80 cm higher than the highest
point of the roof.
•
Use rain cap or wind cowl at the end of the chimney to avoid to come inside
anything(bird,etc…). Distance between raincap and chimney end should be 30-40 cm.
•
The pellet stove can operate in conjunction with the existing multiple chimneys. In
addition, the stove should not be connected at places such as the aspirator chimney
and ventilator.
•
The chimney can be given directly out of the pellet stove at a short distance, or it
can be connected to the existing chimney at short distance.
ATTENTION !!!
THE PIPE AND ELBOWS USED UP TO THE CHIMNEY OUTPUT AND INPUT NEEDS TO BE THE SAME
DIAMETER. BY THE INPUT OF THE CHIMNEY A REDUCTION MUST BE USED. MAXIMUM 4 METERS
PIPES AND 2 ELBOWS NEEDS TO BE USED. PIPE JOINTS SHOULD BE TAPED TO CONNECTOR OR
ALUMINUM BAND.