background image

8. Cycling a battery

9. Battery balancing

10. Battery storage

11. View Data

12. Balancing status

13. Graphic screen

14. Advanced Setup (+)

TYPE

LIPO

CHARGE

DISCHARGE

CYCLE

BALANCE

STORAGE

VIEW

DATA

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

1) Connect the battery

2) Press and hold CYCLE

3) Battery check 

4) Cycle screen: Charging

5) Cycle screen: Discharging

TYPE

LIPO

BALANCING

STATUS

GRAPHIC

STOP

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

CYCLING D->C (1/1): DISCHARGING

6) Cycle Complete

TYPE

LIPO

BALANCING

STATUS

GRAPHIC

OK

<

>

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

CYCLING COMPLETE (1/1): CUT-OFF

CYCLES

1

START

C->D

START

D->C

START

D->C->D

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

BATTERY CHECK...

< OK >

-

+

TYPE

LIPO

BALANCING

STATUS

GRAPHIC

STOP

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

CYCLING C->D (1/1): CHARGING

BATTERY CHECK...

< OK >

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

1) Connect the battery

2) Press and hold BALANCE

3) Battery check 

4) Balancing Status Screen

5) Balancing Screen

BALANCING STATUS

BACK

START

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

GAP

0.005V

VOLTAGE

15.262V

C1: 

4.206V  1.1m

Ω

C2: 

4.145V  1.1m

Ω

C3: 

-

C4: 

-

C5: 

-

C6: 

-

BALANCING

BACK

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

GAP

0.005V

DURATION

7:03

C1: 

4.206V  1.1m

Ω

C2: 

4.145V  1.1m

Ω

C3: 

-

C4: 

-

C5: 

-

C6: 

-

6) Balancing Complete

BALANCING COMPLETE

BACK

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

GAP

0.000V

DURATION

12:03

C1: 

4.200V  1.1m

Ω

C2: 

4.200V  1.1m

Ω

C3: 

-

C4: 

-

C5: 

-

C6: 

-

TYPE

LIPO

CHARGE

DISCHARGE

CYCLE

BALANCE

STORAGE

VIEW

DATA

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

4) Storage screen: discharging

STOP

TYPE

LIPO

BALANCING

STATUS

GRAPHIC

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

STORAGE: DISCHARGING

6) Storage Complete

TYPE

LIPO

CHARGE

DISCHARGE

CYCLE

BALANCE

STORAGE

VIEW

DATA

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

BATTERY CHECK...

< OK >

1) Connect the battery

2) Press and hold STORAGE

3) Battery check 

5) Storage screen: charging

TYPE

LIPO

BALANCING

STATUS

GRAPHIC

STOP

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

STORAGE: CHARGING

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

STORAGE COMPLETE: VOLTAGE

BALANCING

STATUS

GRAPHIC

OK

<

>

TYPE

LIPO

CHARGE

DISCHARGE

CYCLE

BALANCE

STORAGE

VIEW

DATA

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

BALANCING STATUS

BACK

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

GAP

0.005V

VOLTAGE

15.262V

C1: 

4.206V  1.1m

Ω

C2: 

4.145V  1.1m

Ω

C3: 

-

C4: 

-

C5: 

-

C6: 

-

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

DELTA PEAK

20mV

BALANCING

On

CHARGE 

END VOLTAGE

3.2V

DISCHARGE

END VOLTAGE

2.8V

MAX.

TEMPERATURE

60°C

TRICKLE

CHARGE

OFF

MORE

HOME

ASSISTANT

START

V

T

Act Vol: 

8.40V 

    Act. Time: 

000:51

HIDE

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

BEEP

OFF

MELODY

1

LCD 

CONTRAST

4

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

BACK

FACTORY

RESET

THEME

COLOR

HOME

SAFETY TIME

500min

TEMPERATURE

SCALE

C

TYPE

LIPO

CHG

5.0A

DCHG

1.0A

CELLS

2

+

CAPACITY

5000

BACK

CHARGE

DELAY

HOME

Make sure that the battery is properly connected to the charger, charge leads 

and balancing connector (if available) and that the parameters are compatible 

with your battery.

Make sure that the battery is properly connected to the charger, charge 

leads and balancing connector and that the parameters are compatible with 

your battery.

Make sure that the battery is properly connected to the charger, charge leads and 

balancing connector (if available) and that the parameters are compatible with 

your battery.

Press the view data 

button to display the 

final data from the last 

function which has 

been used.

When a LiPo, LiFe or 

LiIon battery is 

connected and while it 

is charging or dischar-

ging, you can press the 

balancing status 

button to display the 

current balance status 

of the battery.

While the battery is 

charging or dischar-

ging, you can press the 

graphic button to 

display a graphic 

showing the voltage 

curve of the battery 

since the function was 

started.

We recommend always using the 

BALANCING 

function for LiPo, 

LiFe and LiIon batteries, the 

balancing connector must be 

connected if balancing is on. 

(!) Safety during charging is 

diminished if balancing is disab-

led.

Do not let batteries connected to 

the charger for extended period 

of time if 

TRICKLE CHARGE

 is 

enabled.

The 

SAFETY TIMER

 works for all 

functions of the charger.

The 

THEME COLOR

 setting allows 

you to change the interface 

display color.

The 

CHARGE DELAY

 setting 

allows you to set a cooldown 

period after discharge during 

battery cycling.

Battery cycling will make charge/discharge cycles to your battery; this is useful 

to restore its performance after long periods of storage for example. The cycling 

function uses the same parameters as those that have been setup for charge or 

discharge. 

This function is meant for LiPo, LiFe or LiIon batteries. You can use this function 

to check the current charge status of your batteries. If the battery is unbalanced 

(uneven voltage between the cells) the charger will equalize the cell’s voltage.

This function will charge or discharge the battery to an optimal level to limit 

potential damage to the battery due to storage. With LiPo/LiFe/LiIon batteries the 

charger will either charge or discharge the battery so they reach the optimal 

level. With NiMH/NiCd the charger will first discharge the battery and then 

recharge it to 50% of the user adjusted capacity. The storage function uses the 

same parameters as those that have been setup for charge or discharge. 

After pressing and holding the cycle button and if no problems are detected a 

new screen will be displayed where you can choose the number of cycle and 

what type of cycle you want to make. 

If no problems are detected, the status screen will appear, indicating the current 

status of the battery. 

If no problems are detected, the storage function will start. Discharge and then 

charge mode for NiMH/NiCd . Charge or discharge mode for LiPo/LiFe/LiIon 

depending on their charge level.

Press the charge-discharge, discharge-charge or discharge-charge-discharge 

button to start the cycling.

If your battery is unbalanced you can start the balancing process by pressing 

the start button.

Press and hold the balance button, the battery check screen will be displayed. 

Press and hold the storage button, the battery check screen will be displayed.

The following screen gives you access to advanced parameters, only modify 

these settings if you understand their purpose and implications.

Once the cycling is completed, the final discharge data will be displayed.

Once the balance is completed, the final data will be displayed.

Once the storage function is completed, the final data will be displayed.

The status screen will appear, indicating the current status of the battery.

Summary of Contents for ADVANTAGE TOUCH DUO V-MAX

Page 1: ...entsprechende Auswahl von der Navigationsleiste angezeigt Hier k nnen alle Einstellungen f r einen Kanal vorgenommen und eine Funktion gestartet werden Split View Illustration 2 In der Split View Ans...

Page 2: ...arantie Die Garantie erstreckt sich ausschlie lich auf Produkte die bei einem autorisierten Team Orion H ndler erworben wurden Verk ufe an dritte werden von dieser Garantie nicht gedeckt Garantieanspr...

Page 3: ...bel an 8 Starten Sie die gew nschte Funktion auf dem Ladeger t Fran ais 1 Raccordez le cordon d alimentation au chargeur 2 Branchez la fiche du cordon dans une prise de courant secteur 3 Trouvez les d...

Page 4: ...ght 2013 Team Orion Please visit www teamorion com touchadvance for more information BALANCING BOARD HP PQ TP FP 4S XH EH HP PQ TP FP 5S XH EH HP PQ TP FP 6S XH EH HP PQ TP FP 3S XH EH HP PQ TP FP 2S...

Page 5: ...e charge screen will appear indicating the current status of the battery If no problems are detected the discharge screen will appear indicating the current status of the battery Never leave the charg...

Page 6: ...atible with your battery Make sure that the battery is properly connected to the charger charge leads and balancing connector if available and that the parameters are compatible with your battery Pres...

Page 7: ...AND PEAK TEMP GELADEN DAUER STROM Sobald der Akku vollgeladen ist erscheinen die detaillierten Lade Daten Sobald der Akku vollst ndig entladen ist erscheinen die detaillierten Entlade Daten Das Ladege...

Page 8: ...Einstellungen zu Ihrem Akku passen Stellen Sie sicher dass der Akku korrekt angeschlossen ist Ladekabel und Balancer Anschluss und dass die Einstellungen zu Ihrem Akku passen Stellen Sie sicher dass...

Page 9: ...ION PB 1 2 4 S1 NiMH NiCd LiPo LiFe LiIon Pb S2 1 15 1 6 Lipo LiFe S3 S4 S5 3 5 6 7 www teamorion com Copyright 2013 Team Orion LIPO 5 0A 1 0A 2 5000 S1 S2 S3 S4 S5 2 7 4V ENTER 5000MAH ENTER 5 0A ENT...

Page 10: ...0 LIPO 5 0A 1 0A 2 5000 LIPO 5 0A 1 0A 2 5000 8 9 10 11 12 13 14 1 2 3 4 5 D C 1 1 6 OK 1 1 CUT OFF 1 C D D C D C D C D 1 1 1 2 3 4 5 0 005V 15 262V C1 4 206V 1 1m C2 4 145V 1 1m C3 C4 C5 C6 0 005V 7...

Page 11: ...n les manipulant Utilisez le chargeur dans un endroit bien ventil l cart des personnes et des mati res inflammables Si la batterie r agit de fa on anormale pendant la charge ou la d charge d branchez...

Page 12: ...Si la batterie est d s quilibr e variation de tension entre les l ments le chargeur quilibre la batterie Cette fonction charge ou d charge la batterie un niveau optimal pour viter les dommages dus au...

Page 13: ...o li toccate Utilizzate il caricabatterie in un posto ben ventilato lontano dalla gente e dei materiali infiammabili Se la batteria a reazioni anomale durante la carica o la scarica come perdita di ga...

Page 14: ...to attuale delle vostre batteria Se la batteria e sbilianciata tensione divergente fra le celle il caricabatterie equalizza la batteria Questa funzione carica o scarica la batteria a un livello ottima...

Page 15: ...Urladdningsstr m 2 Tryck in och h ll laddningsnapp intryckt 3 Batteri kontroll OK 4 Laddningssk rm 5 Laddning klar BALANS STATUS GRAFIK STOP LADDNING BALANS STATUS GRAFIK OK LADDNING KLAR CC CV N r l...

Page 16: ...ion om senast anv nda funktion N r ett LiPo eller LiFe batteri r anslutet och laddning eller urladdning sker kan man trycka in knappen balanseringsstatus f r att visa den nuvarande balansen mellan oli...

Reviews: