No Water
In the event of ‘NO WATER’ the safety Lockout will operate and
the red tell tale will flash.
After refilling with water the unit must be reset.
Remove the fuse and after 30 seconds, replace the fuse. The red
tell-tale will show a continuous light to indicate that the unit has
reset
Failure to comply with these fitting instructions will
invalidate the manufacturers warranty and may damage the
unit and the vehicle.
Cleaning Instructions
Daily: Empty the waste water tray into a foul water drain and rinse
with clean water.
Monthly: Empty your HANDEMAN XTRA® and flush through with
clean water. Wipe all surfaces with a mild detergent. Flush out the
waste water tray with a mild detergent and rinse with clean water.
Note the spray nozzle is removable for cleaning.
HANDEMAN XTRA® Technical Specification
Dimensions;
Width
310 mm
Height
370 mm
Depth
220 mm with waste water tray
closed
370 mm with waste water tray
open
Voltage: HMX12: 12V 220W
18 A @ 14 VDC 30 amp strip
link fuse
HMX24: 24V 250W
10A @ 27 VDC 15 amp fuse
HMXLW: 12V 90W
8A @ 14 VDC Accessory
socket plug
Water Capacity
3.3 Litres
3 litres useable
Water temperature
42°C +/- 2°C.
Heating time 30 minutes approx from 12°C to 42°C
Weight
4 Kg empty
7 kg full
Water Not Suitable for Drinking
TEAL PATENTS LTD
UNIT 2 WATERLOO AVENUE, CHELMSLEY WOOD INDUSTRIAL ESTATE,
CHELMSLEY WOOD, BIRMINGHAM, B37 6QQ, ENGLAND
TEL: +44 (0) 121 770 0593 FAX: +44(0) 121 770 0385
Email:
www.tealwash.com