background image

 

 

Standard HMX24 

 

When the vehicle is turned off the battery state is quiescent at 

24V. 

 

When switched on, the alternator will raise the battery output 

to 27V. 

 

The software in the Handeman Xtra® will see this rise and 

switch the unit on when 27 volts is detected. The Handeman 

Xtra® will then continue to work until the vehicle is switched 

off and the unit will see the battery output drop back to 24V 

and will cut out at 25.5 V. 

 

The battery will not be therefore be drained by the Handeman 

Xtra®   

**Non-voltage sensing 

The non-voltage sensing Handeman unit model number is 

HMX12NV. 

With the advent on many modern vans of Smart Regenerative 

Charging technology, the alternator will have the ability to see the 

state of battery charge and decide to switch on and off during the 

journey – thus saving fuel. 

The consequence of this, is to potentially keep switching the 

Handeman Xtra® on and off during the journey, which reduces the 

heating time available. 

To overcome this issue, Teal have introduced non-voltage 

sensing version. The Handeman Xtra® will, when connected to the 

vehicle’s battery, switch on and keep running, which could 

potentially run the battery flat. 

Therefore a switch or relay must be introduced between the 

battery and the Handeman, enabling it to be switched off 

either manually or automatically. 

The choice of switches or relays is down to customer preference 

 

 

 

 

 

 

 

Summary of Contents for Handeman Xtra

Page 1: ...Accurate temperatures of 42 C 2 C No Water safety lockout Battery safe with voltage sensing Simple 2 wire installation Complete with correct fuse and fuse holder More than 15 ten second hot washes per filling Wash under running hot water 3 3 litres water tank 3 litres useable Hygienic finger tip operated tap Installation kit Versions for both 12 and 24 Volt power supply HMX12 HMX24 Electrical inte...

Page 2: ...e advent on many modern vans of Smart Regenerative Charging technology the alternator will have the ability to see the state of battery charge and decide to switch on and off during the journey thus saving fuel The consequence of this is to potentially keep switching the Handeman Xtra on and off during the journey which reduces the heating time available To overcome this issue Teal have introduced...

Page 3: ...r the 15 amp fuse for 24V as supplied Black wire To ive terminal or to a substantial chassis earth point ensuring a contact Check that all connections are secure Important Keep the wiring as short as possible to prevent voltage drop for this may affect the operation of the unit Testing After replacing the Waste Safe fill the unit with 3 3 litres of clean water Do not fill above the fill line Make ...

Page 4: ...mild detergent Flush out the waste water tray with a mild detergent and rinse with clean water Note the spray nozzle is removable for cleaning HANDEMAN XTRA Technical Specification Dimensions Width 310 mm Height 370 mm Depth 220 mm with waste water tray closed 370 mm with waste water tray open Voltage HMX12 12V 220W 18 A 14 VDC 30 amp strip link fuse HMX24 24V 250W 10A 27 VDC 15 amp fuse HMXLW 12V...

Page 5: ...3 LIFT GENTLY UPWARDS FROM THE BOWL SIDES 4 SWING THE BOTTOM OF THE BOWL OUT 5 ONCE THE BOWL IS FREE LIFT OUT 6 TIP FROM THE SLOT INTO A FOWL WATER DRAIN 7 TO REPLACE SIT THE BOWL ON THE LOWER FRONT RAIL AND PUSH AT THE BASE SNAP TOP CLOSED 8 TAP NOZZLE CAN BE REMOVED FOR CLEANING Fitting optional soap and towel holder Screws Supplied ...