4.2.5
Switch ON/OFF to processor
Switch ON
1. Connect the power input socket with 200~240V AC by power cord.
2. Release the Emergency Stop button.
3.
Switch the Mains Switch to ON from rear panel
Touch screen will power on and show the standby interface.
4. Switch on the Processor by pressing the I/O button for 5 seconds.
a) The I/O LED flash.
b) Touch screen will show the main interface.
c) Heater indicator turn amber, and Temperature of heater start to rise.
5. Check that the correct process button is selected for the task required.
a) The active button is shown on the main interface.
6.
When the Heater Indicator turn green, machine is ready to start process.
Switch OFF
1. Ensure that the Processor operating cycle is completed and the cable splice has been removed
2. Switch OFF the Processor by pressing the I/O button for 5 seconds
a) The I/O LED start to flash.
b) Touch screen will show the shutdown interface.
c) Temperature of heater start to drop.
d) cooling fan keep running
3. When temperature drop to 190°C, cooling fan stop running.
4.
Switch the Mains Switch to OFF from rear panel
DO NOT use E-stop button or main switch directly as normal Switch OFF process, due to it
will reduce Heater life.
OFF/ ON
Summary of Contents for RBK-X1 CE
Page 45: ...RBK X1 CE PN 2234800 2 4 6 Page 44 Rev B Apr 2020 Right Cover Securing Screws 7X...
Page 51: ...RBK X1 CE PN 2234800 2 4 6 Page 50 Rev B Apr 2020 6 Schematic Diagram...
Page 52: ...RBK X1 CE PN 2234800 2 4 6 Page 51 Rev B Apr 2020...
Page 53: ...RBK X1 CE PN 2234800 2 4 6 Page 52 Rev B Apr 2020...
Page 55: ...RBK X1 CE PN 2234800 2 4 6 Page 54 Rev B Apr 2020 9 Declaration of conformity of CE...