ROUTING AND CONNECTING THE SPLITTER OUTPUT FIBERS
The splitter modules are mounted at the top of the 864 termination FDH 3000 cabinet. When a
splitter module is initially installed, the output fibers are routed to the storage panel located at
the bottom of the cabinet. At the storage panel, the output fibers are temporarily “parked” until
they are needed. Service to a subscriber is enabled by removing an unused output fiber from the
storage panel, routing it to the appropriate distribution panel, and then connecting it to the
subscriber port.
8.1
Storing The Splitter Output Fibers
Use the following procedure to store the splitter output fibers.
1. Following installation of a splitter module, locate an open connector pack slot in the
storage panel at the bottom of the cabinet.
2. Insert the connector pack into the unused slot in the storage panel. Refer to the FDH 3000
Plug and Play Splitter Installation Guide (ADCP-96-087) provided with splitter modules
for additional information on installing connector packs in the storage panel.
3. Use the radius limiters to store any excess fiber slack. Refer to
for the routing
guidelines.
Figure 30. Routing Splitter Output Fibers for Storage
21633-B