412-10100
Rev A
51
of 74
Table 13: Crimp height history data (only shown for production mode crimps)
Field
Description
Crimp result
PASS or FAIL from crimp height analysis
Measured crimp height
Crimp height value from the crimp height analysis
UCL
Upper control limit
LCL
Lower control limit
Nominal crimp height
Crimp height desired and set in the part
Control limit
Value calculated or set in the part
Calculate control limit
True or false
Crimp height tolerance
Allowable tolerance set in the part
Table 14: Peak force history data (peak force analysis)
Field
Description
Peak force result
PASS, FAIL, or LEARN from peak force analysis
Force
Peak force value from the peak force analysis
UCL
Upper control limit
LCL
Lower control limit
Sensitivity
Sensitivity setting for the peak force analysis
Table 15: Work index history data (work index analysis)
Field
Description
Work index result
PASS, FAIL, or LEARN from work index analysis
Work index
Work index value from the work index analysis
UCL
Upper control limit
LCL
Lower control limit
Sensitivity
Sensitivity setting for the work index analysis
Table 16: P2P history data (point to point analysis)
Field
Description
P2P result
PASS, FAIL, or LEARN from point to point analysis
Value
Point to point value from the point to point analysis
Table 17: FFT history data (fast Fourier transform analysis)
Field
Description
FFT result
PASS, FAIL, or LEARN from FFT analysis
Value
FFT value from the FFT analysis
Above count
Number of frequencies that are above the mean
Below count
Number of frequencies that are below the mean
Failure code
Code for internal use
Sensitivity
Sensitivity setting for the FFT analysis
Threshold
Threshold level in % for FFT analysis
Force threshold
Actual force value of the threshold