Figure 30
Point -
The plotted point number.
Xbar -
The average force for all connectors of the charted type on the current board.
Var -
The force variability for all connectors of the charted type on the current board. May be R (range) or S
(std. dev.).
# Fail -
The number of connectors that the force was outside of the spec limits for the charted connector type
on the current board.
Time -
Time of day the board was run.
Date -
Date the board was run.
Profile -
Name of profile used to press the charted connector type.
Oper -
Operator name logged on when the board was run.
Prf Rev -
Revision of profile used to press the charted connector type.
Brd Rev -
Revision of board file.
6.4.
Options
See Figure 31 for the following options.
Figure 31
Range Bars -
The range for the data whose average forms a point on the X-bar chart can be displayed on the
X-bar chart. It is represented as a vertical line through the plotted point, with a short horizontal line at the
maximum and minimum readings for the averaged data. Checking this box enables range displaying.
Control Limits -
Checking this box enables the displaying of control limits on the charts.
Spec. Limits -
Checking this box enables the displaying of specification limits (max and min force) on the
charts.
Grid -
This check box enables grid line display on the graphs.
Shaded -
This adds shading between the spec limits and control limits.
Thick Lines -
This thickens the plotted lines.