409-10104
Rev E
12
of 18
5. Insert the splice into the gage. The splice should enter the gage easily.
Figure 6: Inserting splice into secondary crimp gage
1
Secondary crimp gage
2
Color code dot
3
Splice
6. If the splice does not meet the gage test, verify that the proper wire sizes and combinations listed in
Table 2 were used. Cut off the splice, strip the wires, and apply a new splice.
7. If the splice still does not meet the gage test, return the tool to TE for service (see section 6,