EXcel4 Controller
Page 40
4.1.6
Interpretation of XKDX Messages
Event messages will appear on the XKDX screen and are in plain text. Use the up and
down arrows on the PC keypad to view the previous events. All previous events can be
viewed in this way (depending on the number of events memory). Use the left and right
buttons on the PC keypad to display the date and time of the currently displayed event.
For example:
EXcel 10:56
M00123456 A1
The top line is showing the current time (not the time of the last event).
The bottom line shows the last event (note that message types that have been turned off
will not appear). This can be interpreted as follows:
M00123456
Card number 00123456
Card Technology: MICROcard (see table for other codes)
A1
Event Access Granted (see table for other codes)
Location Reader 1
Card type can be of type:
Access result can be of type:
K= Pin Only
M= MICROcard (i.e. TDSi-technology
card)
W= Wiegand
P= Proximity/Hands Free
A= Magnetic swipe
C= 26-bit Wiegand
I= Indeterminate
A= Access granted
B= ID not in memory
C= ID not valid for door
D= ID expired
E= Out of time zone
F= Anti-pass back enforced
G= PIN time-out
H= wrong PIN
I= 4th consecutive wrong PIN
J= man-trap enforced
K= Relay latched off
N= Control card ON
P= Control card OFF
4.1.7
For more details on the XKDX refer to the
EXgarde Toolkit Manual.
General Reader faults:
Ultimately the reader or reader channel on the PCB may be faulty but this can be tested
by using another reader, or connect the reader directly to the PCB with only the cable
that comes with the reader, or only using a very short 2 metre cable to test.
Present or use a different card
–
it could be a faulty card.
Does the reader work OK on another reader channel port?
Try down powering the ACU down and then up again. Try a reset on the ACU.