5. Terminal Connection Method
Pay attention to the input wiring. If it is connected to wrong terminal, the power supply will be damaged.
・
When making connections, the input must be off.
・
terminal must be connected to protective earth (flame ground of the equipment and etc.) by thick wire for
safety and improvement of noise sensitivity.
・
Output current of each connector pin (standard model, /A, /L and /CO2 option model) must be less than 10A
and the output current of each terminal block pin (/T and /TA option model) must be less than 30A.
・
The output load line and input line shall be separated to improve noise sensitivity.
・
When connecting or removing connector, do not apply stress to PCB.
・
Use input/output connector (housing) and the crimp type terminal specified by the table below.
Connector or crimp type terminal is not included with this product.
・
Use recommended crimping tool. (Refer to the following)
Standard Model, /L, /A and /CO2 Option Model (chassis and cover are not drawn)
Input Connector (CN1) / Output Connector (CN51, CN52)
Hand Crimping Tool : YC-930R (JST)
The recommended wire size are AWG #22 ~ #16.
Signal Connector (CN53)
Hand Crimping Tool : YRS-620 (JST)
The recommended wire size is AWG #28 ~ #22.
COMPONENT SIDE
5
3
1
CN1
L
N
INPUT
+ 3
2
1
4
5
- 3
2
1
4
5
OUTPUT
CN51
CN52
CN53
1
3
5
7
2
4
6
8
VR51
LOAD
Connector
Housing
Terminal Pin
Maker
Input
( CN1 )
Output
( CN51 & CN52 )
B3P5-VH(LF)(SN)
VHR-5N
SVH-41T-P1.1
JST
B5P-VH(LF)(SN)
VHR-5N
SVH-41T-P1.1
JST
Connector
Housing
Terminal Pin
Maker
SPHD-002T-P0.5
SPHD-001T-P0.5
CN53
B8B-PHDSS(LF)(SN) PHDR-8VS
JST