FORCED AIR COOLING CONDITION
Components must be cool down. As a guide, an air velocity of more than 2.2m/s is required to flow through
the power supply from C9 and T1 side.
The power supply is considered as a component installed to an equipment.
The equipment must be re-evaluated and make sure to meet allowable component temperature.
ALLOWABLE COMPONENT TEMPERATURE
(*) Electrolytic capacitor. Equipment must be re-evaluated for electrolytic capacitor lifetime.
L
A
B
C
D
E
E
F
F
G
H
I
J
K
K
M
N
Measurement
point
Symbol
Item description
Allowable temperature (°C)
A
CN1
Input connector
105
B
C5
Y capacitor
125
C
C6
X capacitor
110
D
C9
Boost capacitor
80(*)
E
C51/C52
Output capacitor
80(*)
F
C12/C58
Signal capacitor
100(*)
G
L2
Input common mode choke coil
125
H
L3
Boost choke coil
130
I
T1
Transformer
130
J
T2
Transformer
130
K
CN51/CN52
Output connector
105
L
PC401/PC402
Photo coupler
110
M
R108
Power resistor
130
N
R51
Power resistor
130
L