CHAPTER 2
SPECIFICATIONS
2.1 SPECIFICATIONS: 200W/400W Series
ZUP20-
20
ZUP20-
10
ZUP10-
40
ZUP10-
20
ZUP6-
66
ZUP6-
33
ZUP60-
7
0
~
7
0
~
1
2
ZUP60-
3.
5
0
~
3
.5
0
~
6
216
432
210
420
ZUP36-
12
ZUP36-
6
0
~
3
6
0
~
6
0
ZUP120-
3.
6
ZUP120-
1.
8
ZUP80-
5
ZUP80-
2.
5
V
A
W
-
-
mV
mV
mS
-
-
mS
mS
mS
-
-
mA
-
-
-
-
-
-
V
-
-
-
-
-
-
A
-
-
%
A
MODEL
OUTPUT
VOL
T
AGE
(*1)
OUTPUT
CURRENT
(*2)
RA
TED
OUTPUT
POWER
LOAD
REGULA
TION
LINE
REGULA
TION
RMS
RIPPLE
RIPPLE
RECOVER
Y
TIME
(*4)
TEMPERA
TURE
COEFFICIENT
TEMPERA
TURE
DRIFT
(5Hz-1MHz
Bandwi
d
th
)
(p
k
to
p
k
20MHz
Bandwi
d
th
)
LOAD
REGULA
TION
LINE
REGULA
TION
RMS
RIPPLE
TEMPERA
TURE
COEFFICIENT
TEMPERA
TURE
DRIFT
(5Hz-1MHz
Bandwi
d
th
)
INPUT
VO
L
T
AGE
(*8)
INPUT
CURRENT
(*6)
INPUT
CURRENT
HARMONICS
POWER
F
ACT
OR
(TYP)
EFFICIENCY
(*6)
INRUSH
CURRENT
(*7)
100/200
V
VO
L
T
AGE
CURRENT
S
T
A
TUS
UP
PROGRAMMING
RESPONSE
TIME
FULL
LOAD
NO
LOAD
RESOLUTION
ACCURACY
RESOLUTION
ACCURACY
VO
L
T
AGE
CURRENT
CONSTANT
VOL
TAGE
CONSTANT
CURRENT
DOWN
PROGRAMMING
RESPONSE
TIME
PROGRA-
MING(*3)
DISPLAY
OVER
VOL
T
AGE
PROTECTION
(*5)
HOLD
UP
TIME
OUTPUT
PROTECTIONS
INPUT
10
5.
6
/
2
.7
5.3/2.
6
8
0
/
8
4
8
2
/
8
6
15
5.
6
/
2
.7
4.9/2.
4
8
0
/
8
4
8
3
/
8
7
0
~
2
0
30
5.
6
/
2
.7
7
9
/
8
3
0
~
4
0
50
5.
6
/
2
.7
7
9
/
8
2
0
~
6
6
0.005%
+2mV
(*10)
0.005%
+4mV
0.005%
+1mV
(*1
1)
0.005%
+2mV
5
50
30ppm/
C
fro
m
rated
vol
tage
following
30-minute
warm-up
O
0.01%
+2mV
change
in
output
over
8-hour
interval
under
const
ant
line,
load
and
ambient
temperatur
e
following
30-minute
warm-up
50
50
100
5.
6
/
2
.7
7
4
/
7
7
15
15
15
15
15
15
15
5
5
5
5
5
2.
9
/
1
.4
2.9/1.
4
7
5
/
7
9
7
8
/
8
2
7.
5
2.
9
/
1
.4
2.6/1.
3
7
6
/
8
0
7
8
/
8
2
0
~
1
0
15
2.
9
/
1
.4
7
4
/
7
8
0
~
2
0
25
2.
9
/
1
.4
7
3
/
7
7
0
~
3
3
198
396
200
400
200
400
50
3.
0
/
1
.5
6
9
/
7
2
1
5
/
3
0
1
5
/
3
0
1
5
/
3
0
1
5
/
3
0
1
5
/
3
0
1
5
/
3
0
1
5
/
3
0
250
0
-
7
.5
1
350
0
-13
0.
5
400
0
-
2
4
0.
2
0.01
%
+
5mA
fo
r
load
vol
tage
change
equal
to
unit
vol
tage
ratin
g
,
const
ant
input
vol
tage.
0.01%
+2mA
from
85-132V
AC
or
170-265V
AC,
const
ant
load
20mS
at
100V/200V
AC,
rated
output
vol
tage
and
output
current
100ppm/
C
fro
m
rated
current
following
30
minute
warm-up
O
Bette
r
than
0.028%
of
rated
output
vol
tage
0.02%
+
5
mV
0.02%
+
8
mV
0.02%
+
12m
V
0.02%
+
26mV
0.02%
+
35m
V
0.4%
+
40m
A
Bette
r
than
0.03%
of
rated
output
current
0.02%
+5mA
change
in
output
over
8-hour
interval
under
const
ant
line,
load
and
ambient
temperatur
e
following
30
minute
warm-up
3
d
igit
s
(6V
,
20V
,
36V
,
60V
,
80V)
3.
5
d
igit
s
(10V
,
120V)
accuracy:
0.2%
+/
-
2
d
igit
s
3
d
igit
s
accuracy:
0.5%
+/
-
3
d
igit
s
CV/CC,
Alarm,
Fold,
Local/Remote,
ON/OFF
Over
V
olt
age,
Over
T
emperature,
Foldback
8
5
~
265V
AC
Continuous,
4
7
~
63Hz
Complie
s
w
ith
EN61000-3-2,
Class
A
0.99
at
100/200V
AC,
100%
Load
500
0
-
4
0
0.02%+50mV
0.4%+
0.4%+
0.4%+
0.4%
+
15mA
30mA
10m
A
20mA
0
-
8
8
0
-
132
0.02%+80mV
0.
2
750
0
-
6
6
0.
2
100
0
~
6
0
~
1
0
0
~
2
0
0
~
1
.8
0
~
5
20
0
~
3
.6
0
~
2
.5
20
200
70
60
0.
2
800
400
80
80
0.
2
1000
216
432
0
~
8
0
0
~
120