5.5.3
Output control continued
#
Commands
5
:CUR!;
6
:CUR?;
7
:OUTn;
8
:OUT?;
9
:FLDn;
10
:FLD?;
Description
Returns the string
(Set Amper) followed by the present programmed
output current. The programmed value range is shown in table 5-2.
example- SA3.000
SA07.50
SA
Returns the string
(Actual Amper) followed by the actual output current.
The actual current range is the same as the programming range.
example- AA3.000
AA07.50
AA
Sets the output to On or Off.
:OUT1; - Output On
:OUT0; - Output Off
Returns
followed by the output On/Off status.
OT1 - Output is On
OT0 - Output is Off
OT
Sets the Foldback protection to On or Off.
:FLD1; Arm the foldback protection.
:FLD0; Release the foldback protection.
:FLD2; Cancel the foldback protection.
When the foldback protection is activated, :FLD0; will release the
protection and re-arm it while :FLD2; will cancel the protection. If the
protection has not been activated, both commands are the same.
Returns
followed by the Foldback protection status.
FD1 - Foldback is armed
FD0 - Foldback is released
FD
11
:OVPn;
12
:OVP?;
Sets the over-voltage protection level in volts. Over-voltage range settings
are given in table 5-3:
Example - ZUP10-XY :OVP08.4;
Example- OP08.4
Returns the string
followed by the present programmed over-voltage
protection value. The over-voltage range is given in table 5-3.
OP
Model
MIN.
MAX.
ZUP6-XY
0.20
7.50
ZUP10-XY
00.5
13.0
ZUP20-XY
01.0
24.0
Table 5-3: Over-voltage programming range.
ZUP36-XY
01.8
40.0
ZUP60-XY
03.0
66.0
ZUP80-XY
04.0
88.0
ZUP120-XY
006.0 132.0