background image

Low Profile

The Best Power Solution for Display Technologies

The SWS-L series is designed to have a lower 
profile than previous models. With the thin of 
61mm, a 50% size reduction, these can be
mounted in 2U or smaller locations. Compact
size SWS-L is ideal for applications incl.
electronic display, vending machines and self 
service kiosks.

Low Fan Noise

The SWS-L is one of the quietest power supplies 
in their  class. A temperature controlled fan
adjusts  its speed automatically,  based on the 
temperatures surrounding the power supply. This
substantially reduces annoying fan noise and 
wasted power consumption.

One of key purposes of SWS-L is to meet trends in 
LED display technologies. Users will appreciate the 
many features of SWS-L, especially its compact 
size. These supplies are the slimmest in their class. 
Acoustic noise  is substantially reduced, which  is 
important for indoor applications, while wide 
temperature ranges make it ideal for outdoor 
applications. With  full  conformance  to international
safety and EMC standards, designed-in reliability 
and extended field-life span, SWS-L reduces cost of 
ownership by saving the expenditures associated
with maintenance, system  down-time, and repair 
costs.  Overall, Lambda always provides our 
customers with  the  best power solutions  by 
combining extensive industry/market research with 

our advanced R&D expertise, ensuring  that our 
power supplies will continue to evolve with technol-
ogy trends.

Model name identification method

Product line-up

Medically Approved for SWS1000L

Complying fully with EN/UL60601 safety standards
including low earth leakage current and reinforced
isolation,  SWS1000L will also meet class B
EMI and is the ideal choice for  your medical 
power needs.

Wide operating temperature range

--Improvement in output ratings

To operate reliably  in outdoor environments a
wide operating temperature range is necessary.
SWS-L is designed to operate between -20

to 

74

.  At its max. temperature, 74

, 50% of the

max. power rating is guaranteed.

Option                           
Blank : Standard type               
/RF : Reversed fan model
       (Exhausted cooling)                             
Rated Output Voltage
Output Power type
Series Name

600W

1000W

Output Voltage

3.3V

5V

12V
15V
24V
36V
48V
60V

( )=Peak

SWS 600 L–5

p

Output Current

p

120A
120A

53A
43A

27((31))A

18A

13((15))A

10A

Model

SWS600L-3
SWS600L-5

SWS600L-12
SWS600L-15
SWS600L-24
SWS600L-36
SWS600L-48
SWS600L-60

p

Output Current

p

200A
200A

88A
70A

44((51))A

29A

22((25))A

17

Model

SWS1000L-3
SWS1000L-5

SWS1000L-12
SWS1000L-15
SWS1000L-24

SWS1000L-36
SWS1000L-48
SWS1000L-60

We are able to add conformal coating on PCB base on customer 
requirement for some specified applications upon request

Summary of Contents for SWS-L Series

Page 1: ...SWS L Series Compact and high power AC DC power supply...

Page 2: ...All specifications are subject to change without notice...

Page 3: ...Lambda always provides our customers with the best power solutions by combining extensive industry market research with our advanced R D expertise ensuring that our power supplies will continue to evo...

Page 4: ...lation Withstand Voltage Input Output 3 0kVAC 20mA Input FG 2 0kVAC 20mA Output FG 500VAC 100mA 60V model 651VAC 130mA Output CNT ALM AUX 100VAC 100mA for 1min Isolation Resistance Input FG Input Outp...

Page 5: ...VOLTAGE RANGE NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT AND PEAK OUTPUT CURRENT ARE SHOWN ON THE NAME PLATE IN ACCORDANCE WITH THE SPECIFICATIONS 2 COUNTRY OF MANUFACTURE IS SHOWN ON THE NAME PLA...

Page 6: ...Ta 25 C first inrush second inrush Leakage Current typ 11 mA 0 1mA at 115VAC 60Hz 0 2mA at 230VAC 60Hz Output Nominal Voltage VDC 3 3 5 12 15 24 36 48 60 Maximum Current Peak Current 1 A 200 88 70 44...

Page 7: ...2 5 37 MAX 29 AIR FLOW 165 0 5 240 1 3 MAX BOTTOM SIDE SEE NOTE C 150 1 110 0 5 20 FG FG L N 38 0 5 4 M4 2 9 10 10 20 2 1 23 1 17 9 29 165 0 5 BOTH SIDES SEE NOTE C 61 1 11 5 CN2 CN3 LED CN1 AMBDA L A...

Page 8: ...ARY G1 COM COM COM CNT2 TOG NC PV S ALM PC S Vm Vm V V OUTPUT ALARM FAN PFC CIRCUIT RECTIFIER LINE FILTER Sequence Time Chart SWS1000L INPUT VOLTAGE RANGE 85 265VAC FUSE RATING 20A PFC FREQUENCY 130kH...

Page 9: ...azardous voltage These terminals must not be user and service person accessible This power supply is capable of providing hazardous energy output 240VA the end equipment manuafacturer must provide pro...

Page 10: ...and function They are connected to each other in this power supply unit When the pin of CN1 side is shorted the same function pins of CN2 side are also shorted Please note that the function cannot be...

Page 11: ...load line Output current of each terminal screw shall be 60A or less for SWS600L Panel Side Basic connection Local sensing Connect S terminal to Vm terminal and S terminal to Vm terminal SWS600L SWS10...

Page 12: ...ure Detection Circuit ALM Power failure detection circuit is provided ALM Alarm signal will turn High level to indicate the abnormal status when con verter stops Please take note in parallel or N 1 op...

Page 13: ...hort as possible and same length and twisted 1 Adjust the output voltage of each power supply to be same value within 1 or 100mV whichever is smaller 2 Use same length and type of wires for all load l...

Page 14: ...each for 1 minute When testing withstand voltage set current limit of withstand voltage test equipment at 20mA Output chassis and Output Control 100mA The applied voltage must be gradually increased f...

Page 15: ...ut Peak Current For 24V 48V output model please meet the following condi tions Reduce peak current value according to output derating as section 4 2 Input voltage range AC170V 265V Continuous Peak out...

Page 16: ...This power supply has ventilating holes on the front and back side panels Keep these two areas freely as much as possible 2 The maximum allowable penetration for screw is 6mm Incomplete thread of moun...

Page 17: ...m Type Size Conductor part Insulation part UL1007 AWG 28 1 2 0 55 0 60 1 6 UL1007 AWG 26 1 3 0 60 0 65 1 7 UL1007 AWG 24 1 5 0 62 0 67 1 8 Note1 Crimp height at wire barrel should be set to pre determ...

Page 18: ...ent temperature 9 Special instructions for IEC EN UL CSA 60601 1 SWS1000L only 1 These products are designed for continuous operation within an overall enclosure and must be mounted such that access t...

Page 19: ...f use function of the Remote ON OFF control check if the Remote ON OFF control is properly used 7 Check if the built in FAN is not stopped Is FAN stopped by something irregular or etc If FAN stops the...

Page 20: ...Each Manufacturing Company This datasheet has been downloaded from www EEworld com cn Free Download Daily Updated Database 100 Free Datasheet Search Site 100 Free IC Replacement Search Site Convenien...