TDK-Lambda SWS-L Series Manual Download Page 10

10

・All specifications are subject to change without notice.

SWS 

600L, 1000L

Please pay extra attention to the wiring. Incorrect connection 

will damage the power supply.

  Front Panel Explanation

SWS600L

SWS1000L

① V.ADJ : Output voltage adjustment trimmer.

 

(The output voltage rises when a trimmer is turned clockwise.)

 ON : Output (Power on) indication LED

 

(The indicator turns on when the power supply output is in 

normal operating condition.)

 CN1, CN2, CN3 : Remote sensing, ON/OFF control signal, 

current balance signal, power fail alarm, auxiliary output, 

output voltage external control signal. (Refer to 1-2.)

④  

 : Protective earth (Frame ground), M4 screw.

 

(SWS1000L: M4 screw x 2)

 AC input terminal L : Live line (Fuse in line), M4 screw. 

 AC input terminal N : Neutral line, M4 screw. 

 + : + Output terminal

 

(SWS600L: M5 screw x 2 / SWS1000L:

φ

9hall, M4 tapped hall x 2)

 -  :  - Output terminal

 

(SWS600L: M5 screw x 2 / SWS1000L:

φ

9hall, M4 tapped hall x 2)

 C N1,  C N 2 ,  C N 3  C o n n e c t o r  p i n 

Configuration and Function

CN1 and CN2 are same pin confi guration and function. They are 

connected to each other in this power supply unit. When the pin 

of CN1 side is shorted, the same function pins of CN2 side are 

also shorted. Please note that the function cannot be separately 

set with CN1 and CN2.

CN1, CN2

Pin No

Config-

uration

Function

1

+Vm

+OUTPUT VOLTAGE MONITOR 

2

+S

+SENSING

3

-Vm

-OUTPUT VOLTAGE MONITOR

4

-S

-SENSING

5

N.C.

NO  CONNECTION

6

PC

CURRENT BALANCE

7

PV 

ADJUSTMENT OF OUTPUT VOLTAGE

8

COM

GROUND FOR PC AND PV SIGNAL

9

CNT2

REMOTE ON/OFF (2)

10

TOG

GROUND FOR CNT2

CN3

Pin No

Config-

uration

Function

1

COM

GROUND FOR PC AND PV SIGNAL

2

COM

GROUND FOR PC AND PV SIGNAL

3

AUX

AUXILIARY OUTPUT (12V 0.1A)

4

CNT1

REMOTE ON/OFF (1)

5

G2

GROUND FOR AUX AND CNT1

6

G2

GROUND FOR AUX AND CNT1

7

ALM ALARM

8

G1

ALARM  GROUND

CN1, CN2, CN3 Connector & Housing & Terminal Pin 

PART DESCRIPTION

PART NAME

MANUFACT

PIN HEADER

S10B-PHDSS (CN1, CN2)

S8B-PHDSS (CN3)

J.S.T

SOCKET HOUSING

PHDR-10VS (CN1, CN2)

PHDR-8VS (CN3)

J.S.T

TERMINAL  PINS

SPHD-002T-P05 (AWG28~24)

SPHD-001T-P05 (AWG26~22)

J.S.T

HAND CRIMPING  

TOOL

YRS-620 (SPHD-002T-P0.5) 

YC-610R (SPHD-001T-P0.5)

J.S.T

2. Terminal Explanation

L

N

9
7
5
3
1

10

8
6
4
2

9
7
5
3
1

10

8
6
4
2

CN1

CN2

L

N

7
5
3
1

8
6
4
2

CN3

Summary of Contents for SWS-L Series

Page 1: ...SWS L Series Compact and high power AC DC power supply...

Page 2: ...All specifications are subject to change without notice...

Page 3: ...Lambda always provides our customers with the best power solutions by combining extensive industry market research with our advanced R D expertise ensuring that our power supplies will continue to evo...

Page 4: ...lation Withstand Voltage Input Output 3 0kVAC 20mA Input FG 2 0kVAC 20mA Output FG 500VAC 100mA 60V model 651VAC 130mA Output CNT ALM AUX 100VAC 100mA for 1min Isolation Resistance Input FG Input Outp...

Page 5: ...VOLTAGE RANGE NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT AND PEAK OUTPUT CURRENT ARE SHOWN ON THE NAME PLATE IN ACCORDANCE WITH THE SPECIFICATIONS 2 COUNTRY OF MANUFACTURE IS SHOWN ON THE NAME PLA...

Page 6: ...Ta 25 C first inrush second inrush Leakage Current typ 11 mA 0 1mA at 115VAC 60Hz 0 2mA at 230VAC 60Hz Output Nominal Voltage VDC 3 3 5 12 15 24 36 48 60 Maximum Current Peak Current 1 A 200 88 70 44...

Page 7: ...2 5 37 MAX 29 AIR FLOW 165 0 5 240 1 3 MAX BOTTOM SIDE SEE NOTE C 150 1 110 0 5 20 FG FG L N 38 0 5 4 M4 2 9 10 10 20 2 1 23 1 17 9 29 165 0 5 BOTH SIDES SEE NOTE C 61 1 11 5 CN2 CN3 LED CN1 AMBDA L A...

Page 8: ...ARY G1 COM COM COM CNT2 TOG NC PV S ALM PC S Vm Vm V V OUTPUT ALARM FAN PFC CIRCUIT RECTIFIER LINE FILTER Sequence Time Chart SWS1000L INPUT VOLTAGE RANGE 85 265VAC FUSE RATING 20A PFC FREQUENCY 130kH...

Page 9: ...azardous voltage These terminals must not be user and service person accessible This power supply is capable of providing hazardous energy output 240VA the end equipment manuafacturer must provide pro...

Page 10: ...and function They are connected to each other in this power supply unit When the pin of CN1 side is shorted the same function pins of CN2 side are also shorted Please note that the function cannot be...

Page 11: ...load line Output current of each terminal screw shall be 60A or less for SWS600L Panel Side Basic connection Local sensing Connect S terminal to Vm terminal and S terminal to Vm terminal SWS600L SWS10...

Page 12: ...ure Detection Circuit ALM Power failure detection circuit is provided ALM Alarm signal will turn High level to indicate the abnormal status when con verter stops Please take note in parallel or N 1 op...

Page 13: ...hort as possible and same length and twisted 1 Adjust the output voltage of each power supply to be same value within 1 or 100mV whichever is smaller 2 Use same length and type of wires for all load l...

Page 14: ...each for 1 minute When testing withstand voltage set current limit of withstand voltage test equipment at 20mA Output chassis and Output Control 100mA The applied voltage must be gradually increased f...

Page 15: ...ut Peak Current For 24V 48V output model please meet the following condi tions Reduce peak current value according to output derating as section 4 2 Input voltage range AC170V 265V Continuous Peak out...

Page 16: ...This power supply has ventilating holes on the front and back side panels Keep these two areas freely as much as possible 2 The maximum allowable penetration for screw is 6mm Incomplete thread of moun...

Page 17: ...m Type Size Conductor part Insulation part UL1007 AWG 28 1 2 0 55 0 60 1 6 UL1007 AWG 26 1 3 0 60 0 65 1 7 UL1007 AWG 24 1 5 0 62 0 67 1 8 Note1 Crimp height at wire barrel should be set to pre determ...

Page 18: ...ent temperature 9 Special instructions for IEC EN UL CSA 60601 1 SWS1000L only 1 These products are designed for continuous operation within an overall enclosure and must be mounted such that access t...

Page 19: ...f use function of the Remote ON OFF control check if the Remote ON OFF control is properly used 7 Check if the built in FAN is not stopped Is FAN stopped by something irregular or etc If FAN stops the...

Page 20: ...Each Manufacturing Company This datasheet has been downloaded from www EEworld com cn Free Download Daily Updated Database 100 Free Datasheet Search Site 100 Free IC Replacement Search Site Convenien...

Reviews: