background image

Revision F : November 2013

3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4

LZS-A

A1500-33  Power  Supply

Page. 1

Table  of  Contents

1)  Safety  and  Recommended  Practices

2

1.1

General safety instructions

2

1.2

Safety Agency Approvals

2

2)  RATINGS AND SPECIFICATIONS

4

3)  FEATURES

6

4)  GUIDE TO APPLICATION

8

4.1  

Safety Notice

8

4.2  

Input Voltage

8

4.3  

Output Voltage

8

4.4  

Overvoltage Protection Circuit Adjustment

8

4.5  

Overtemperature and Overvoltage Shutdown

8

4.6  

Auxiliary Control and Alarm Signals

8

5)  FIGURES

9

Summary of Contents for LZS-A1500-3

Page 1: ...LZS A1500 3 POWER SUPPLY Installation Operation and Maintenance Manual IM L LZSA1500 3 3 November 2013 Revision F...

Page 2: ......

Page 3: ...Practices 2 1 1 General safety instructions 2 1 2 Safety Agency Approvals 2 2 RATINGS AND SPECIFICATIONS 4 3 FEATURES 6 4 GUIDE TO APPLICATION 8 4 1 Safety Notice 8 4 2 Input Voltage 8 4 3 Output Vol...

Page 4: ...gemeine Sicherheitsanweisungen Dieses Netzteil ist ein Primaerschaltregler Geraet f r Applikationen mit Verschmutzungsgrad 2 Eine passende mechanische Abdeckung und Brandschutzumhuellung ist in der En...

Page 5: ...ecke vorgesehen und duerfen nicht abgedeckt werden 9 Fremdgegenst nde oder Teile niemals in Gehaeuseoeffnungen bringen es besteht Gefahr durch moeglichen elektrischen Schlag der ggf Personenschaeden z...

Page 6: ...0 AM at 1kHz Power Frequency Magnetic Field IEC61000 4 8 3 A m Voltage Dips Short Variations IEC61000 4 11 5 of nom line for 5 cycles Criteria A 40 for 5 cycles Criteria A 70 for 25 cycles Criteria A...

Page 7: ...wer 220VAC mS 10 Ride through Full Power 220VAC mS 20 Voltage Sag Immunity Full Power 220VAC Semi F47 compliant Load Transient Response 1 of Vo 1A S Recovers to within 25 step load change 0 2 in 1 25...

Page 8: ...ible signal connected between pins 6 and 7 of D connector see Fig 9 Signals Isolation Pins 6 and 7 are fully isolated from all other power supply terminals Signal Logic Logic zero below 0 7 V short ci...

Page 9: ...d Mounting One mounting surface mounting position not restricted Maximum allowable penetration into power supply is 1 4 Requires No M4 metric hardware supplied with unit Input and Output Connections T...

Page 10: ...output voltage above 24 0V ensure that there is sufficient OVP margin with respect to the output voltage to avoid nuisance tripping 4 4 OVERVOLTAGE PROTECTION CIRCUIT ADJUSTMENT The overvoltage protec...

Page 11: ...3055 Del Sol Blvd San Diego CA 92154 1 800 LAMBDA 4 LZS A A1500 3 3 Power Supply Revision F November 2013 Page 9 Figure 1 PIN Assignments for TB201 and chassis mounted D connector 5 Figures...

Page 12: ...ZS A A1500 3 3 Power Supply Revision F November 2013 Page 10 Figure 3 Typical Remote Sense Connection Figure 2 Typical Local Sense Connection LS Local Sense S Remote Sense LS Local Sense S Remote Sens...

Page 13: ...F November 2013 Page 11 Figure 5 Remote Voltage Control with an External Programming Resistor or Voltage Source Remote Sensing Figure 4 Remote Voltage Control with an External Programming Resistor or...

Page 14: ...LZS A A1500 3 3 Power Supply Revision F November 2013 Page 12 Figure 6 Parallel Operation...

Page 15: ...3055 Del Sol Blvd San Diego CA 92154 1 800 LAMBDA 4 LZS A A1500 3 3 Power Supply Revision F November 2013 Page 13 Figure 7 Series Operation...

Page 16: ...LZS A A1500 3 3 Power Supply Revision F November 2013 Page 14 Figure 8 Outline Drawing...

Page 17: ...5 Del Sol Blvd San Diego CA 92154 1 800 LAMBDA 4 LZS A A1500 3 3 Power Supply Revision F November 2013 Page 15 Figure 9 Remote Output On Off Control Figure 10 Input Good Inverter Good Output Good Sign...

Reviews: