3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4

LZS-A

A1500-33  Power  Supply

8. Openings in the product case are designed

for ventilation and must not be obstructed

when the product is installed and/or operated.

9. Never push objects of any kind into the

product through openings in its case as this

could result in electric shock or fire hazard.

10. Use copper stranded wire only, 12 to 14

AWG rated at 105°C for the AC input. All

strands must be secured in the terminal block

to avoid potential danger of short circuit.

11. Properly torque AC input terminals to 9 in-lb. 

12. An internal fuse protects the unit and

must not be replaced by the user. In case

of internal defect, the unit must be returned

to the manufacturer. 

13. The output of this power supply is haz-

ardous and must not be user accessible in

the end use equipment. The (+) or (-) output

can be earthed. Use wire rated at 105°C

and sized for 150% of the rated load.

14. The unit contains components that

require special disposal. Make sure that the

unit is properly disposed of at the end of its

service life. 

1.2  Safety  Agency  Approvals  

Regulatory agency compliance applies only

for operating frequencies between 47-63Hz.

No safety agency approvals for 100-380VDC

operation. 

This product is approved to UL 60950-

1/CAN CSA C 22.2 No. 60950-1-07

Second Edition, UL 508, Seventeenth

Edition, EN 60950-1:2006+A11, IEC

60950-1:2005, FM. 

The CE Marking, when applied to the prod-

uct, indicates conformance to the provi-

sions of the following European Directives: 

2006/95/EC 

Low Voltage Directive 

2008/108/EC EMC 

Directive

8. Oeffnungen und Lochungen am Gehaeuse

sind fuer Lueftungszwecke vorgesehen und

duerfen nicht abgedeckt werden. 

9. Fremdgegenstände oder Teile niemals in

Gehaeuseoeffnungen bringen, es besteht

Gefahr durch moeglichen elektrischen

Schlag der ggf. Personenschaeden zur

Folge haette. 

10. Als Netzanschluss ist eine flexible

Kupferleitung (Litze) mit 2,5 mm² Mindest-

Querschnitt zu verwenden die bis 105°C

zugelassen ist. Alle Adern sind im

Anschlussklemmblock zu sichern damit

Gefahren von Kurzschluessen vermieden werden.

11. Empfohlenes Drehmoment für die AC

Anschlussklemmen ist 1,2Nm. 

12. Eine interne Geraete - Absicherung ist

eingebaut. Diese sollte nicht durch den

Anwender getauscht werden. Bei Defekt

des Geraetes ist dieses zu Servicezwecken

an den Hersteller oder dessen zugelassene

Servicestelle zurueckzugeben. 

13. Das Geraet liefert gefaehrliche

Energieinhalte und Spannungen, die

Anschluesse sind in der Endanwendung

beruehrungsfrei einzubauen. Es kann

entweder der (+) oder der (-) Anschluss

geerdet werden. Dafuer sind geeignete

Kabel mit 105°C Temperaturfestigkeit und

150% Ueberlastfestigkeit zu beruecksichtigen.

14. Das Geraet enthaelt Bauteile die nach

geltendem nationalem Recht getrennt zu

entsorgen sind. Bitte beachten Sie die

sichere und bestimmungsgemaesse

Entsorgung am Ende der Produktlebenszeit. 
1.2  Sicherheitszulassungen

Die amtlichen Zulassungen treffen zu für

Anwendungen im Frequenzbereich von 47

bis 63 Hz.

Es bestehen keine Zulassungen für den

DC- Betrieb im Bereich 100 bis 380VDC.

Das Geraet is zugelassen nach UL 60950-

1/CAN CSA C 22.2 No. 60950-1-07

Second Edition, UL 508, Seventeenth

Edition, EN 60950-1:2006+A11, IEC

60950-1:2005, FM. 

Die CE Kennzeichnung, wenn auf dem

Geraet angebracht, zeigt

Uebereinstimmung mit den folgenden EU

Richtlinien: 

2006/95/EC Niederspannungsrichtlinie

2008/108/EC EMV 

Richtlinie 

Page. 3

Revision F : November 2013

Page. 3

Revision F : November 2013

Summary of Contents for LZS-A1500-3

Page 1: ...LZS A1500 3 POWER SUPPLY Installation Operation and Maintenance Manual IM L LZSA1500 3 3 November 2013 Revision F...

Page 2: ......

Page 3: ...Practices 2 1 1 General safety instructions 2 1 2 Safety Agency Approvals 2 2 RATINGS AND SPECIFICATIONS 4 3 FEATURES 6 4 GUIDE TO APPLICATION 8 4 1 Safety Notice 8 4 2 Input Voltage 8 4 3 Output Vol...

Page 4: ...gemeine Sicherheitsanweisungen Dieses Netzteil ist ein Primaerschaltregler Geraet f r Applikationen mit Verschmutzungsgrad 2 Eine passende mechanische Abdeckung und Brandschutzumhuellung ist in der En...

Page 5: ...ecke vorgesehen und duerfen nicht abgedeckt werden 9 Fremdgegenst nde oder Teile niemals in Gehaeuseoeffnungen bringen es besteht Gefahr durch moeglichen elektrischen Schlag der ggf Personenschaeden z...

Page 6: ...0 AM at 1kHz Power Frequency Magnetic Field IEC61000 4 8 3 A m Voltage Dips Short Variations IEC61000 4 11 5 of nom line for 5 cycles Criteria A 40 for 5 cycles Criteria A 70 for 25 cycles Criteria A...

Page 7: ...wer 220VAC mS 10 Ride through Full Power 220VAC mS 20 Voltage Sag Immunity Full Power 220VAC Semi F47 compliant Load Transient Response 1 of Vo 1A S Recovers to within 25 step load change 0 2 in 1 25...

Page 8: ...ible signal connected between pins 6 and 7 of D connector see Fig 9 Signals Isolation Pins 6 and 7 are fully isolated from all other power supply terminals Signal Logic Logic zero below 0 7 V short ci...

Page 9: ...d Mounting One mounting surface mounting position not restricted Maximum allowable penetration into power supply is 1 4 Requires No M4 metric hardware supplied with unit Input and Output Connections T...

Page 10: ...output voltage above 24 0V ensure that there is sufficient OVP margin with respect to the output voltage to avoid nuisance tripping 4 4 OVERVOLTAGE PROTECTION CIRCUIT ADJUSTMENT The overvoltage protec...

Page 11: ...3055 Del Sol Blvd San Diego CA 92154 1 800 LAMBDA 4 LZS A A1500 3 3 Power Supply Revision F November 2013 Page 9 Figure 1 PIN Assignments for TB201 and chassis mounted D connector 5 Figures...

Page 12: ...ZS A A1500 3 3 Power Supply Revision F November 2013 Page 10 Figure 3 Typical Remote Sense Connection Figure 2 Typical Local Sense Connection LS Local Sense S Remote Sense LS Local Sense S Remote Sens...

Page 13: ...F November 2013 Page 11 Figure 5 Remote Voltage Control with an External Programming Resistor or Voltage Source Remote Sensing Figure 4 Remote Voltage Control with an External Programming Resistor or...

Page 14: ...LZS A A1500 3 3 Power Supply Revision F November 2013 Page 12 Figure 6 Parallel Operation...

Page 15: ...3055 Del Sol Blvd San Diego CA 92154 1 800 LAMBDA 4 LZS A A1500 3 3 Power Supply Revision F November 2013 Page 13 Figure 7 Series Operation...

Page 16: ...LZS A A1500 3 3 Power Supply Revision F November 2013 Page 14 Figure 8 Outline Drawing...

Page 17: ...5 Del Sol Blvd San Diego CA 92154 1 800 LAMBDA 4 LZS A A1500 3 3 Power Supply Revision F November 2013 Page 15 Figure 9 Remote Output On Off Control Figure 10 Input Good Inverter Good Output Good Sign...

Reviews: