29
83532002 Rev H
3.4. Rack Mounting
The Genesys
TM
Power Supply Series is designed to fit in a standard 19” equipment rack.
3.4.1. To Install the Power Supply in a Rack:
Use the front panel rack-mount brackets to install the Power Supply in the rack.
Use a support bar to provide adequate support for the rear of the Power Supply. Do not
obstruct the air exhaust at the rear panel of the unit.
3.4.2. Rack Mount Slides (optional, customer provided)
CAUTION
Ensure that the screws used to attach the slides are
NOT
longer than 8mm.
Use rack-mount slides (General Devices P/N C230-S-122 or equivalent) to install the
unit in a standard 19” wide equipment rack. For racks with longer depth, contact the
rack-mount slide provider for the proper rack-mount slide to use.
To install the unit into a standard 19” wide equipment rack, refer to rack-mount slide-to-
unit assembly instructions. Use four M5x0.8-8mm long (max) pan head screws to
attach a slide to one side of the unit. To prevent damage, use the specified screw
length only (8mm max.).
3.5. Location, Mounting and Cooling
This Power Supply is fan cooled. The air intake is at the front panel and the exhaust is at
the rear panel. Upon installation, allow cooling air to reach the front panel ventilation
inlets. Unrestricted air space at the front and the rear of the unit is necessary for proper
cooling of Power Supply.
The Power Supply should be used in an area where the ambient temperature does not
50°C.
CAUTION
When an energized load (eg. battery) is connected to the Power Supply
Output always make sure that the Power Supply fans are operating.
Before turning OFF the AC Input power switch always make sure that the
Output is OFF and the energized load is disconnected from the Output.
See Section 3.9 for details
3.6. AC Source Requirements
The Genesys
TM
Series 10kW/15kW power supply can be operated from a nominal three-
phase 208VAC, 400VAC or 480VAC, 4 wire, 47–63 Hz AC input. The AC input voltage
range and current required for each model is specified in Chapter 2, Section 2.2 (Input
Characteristics). Ensure that under heavy load, the AC voltage supplied to the Power
Supply does not fall below the specifications described in Chapter 2, Section 2.2 (Input
Characteristics).
3.7. AC Input Power Connection
CAUTION
Connection of this Power Supply to an AC power source should be made
by an electrician or other qualified personnel. Do not exceed the torque
specified on the AC Input stud terminals.
Summary of Contents for GENESYS 15KW