26
83532002 Rev H
2.12. EMC
CE Mark
1. ESD
---
EN61000-4-2 (IEC 1000-4-2): Air-disch. +/-8kV, contact disch. +/-4kV
2. Fast transients
---
EN61000-4-4 (IEC 1000-4-3): +/-2kV: AC Power, 2kV: DC Output
3. Surge immunity
---
EN61000-4-5 (IEC 1000-4-5): 1kV line-to-line, 2kV line-to-ground
4. Conducted immunity
---
EN61000-4-6 (IEC 1000-4-6): 10Vrms
5. Radiated immunity
---
EN61000-4-3 (IEC 1000-4-3): 10V/m
6. Power Frequency Magnetic Field
---
EN61000-4-8: 30A/m
7. Conducted emission
---
EN55011A, FCC part 15J-A
8. Radiated emission
---
EN55011A, FCC part 15J-A
Note: EMC Approval for: Vout < 30V @ 208VAC/400VAC
30V
≤
Vout
≤
600V @ 208VAC/400VAC/480Vac
2.13. Safety
1. Applicable Standards
---
UL/cUL 60950-1, EN60950-1 recognized (CB Scheme)
All Outputs are Hazardous.
For Vout
≤
400VDC: IEEE, LAN, USB, IS510 or IS420 are SELV.
CE mark for all inputs (208VAC, 400VAC, 480VAC).
2. Insulation resistance
---
20 Megohms typical at 500Vdc (Output terminals-to- Chassis), 25°C, 70% Relative Humidity