INSTRUCTION MANUAL
EVS300W/600W
Series
TDKLambda
<Page>
EVS600W
Output constant current adjustment trimmer can adjust output constant current value.
Please do not set output constant current value more than a maximum output current. Might cause damage of
the product.
Output constant current adjustment trimmer is primary side component.
Output constant current adjustment trimmer should be adjusted by skilled person once this product to be
installed into the equipment.
Method of Constant Current Setting
(1)Check the output voltage and the output current are normal after the product power on.
Set the load current with your target current value within 50100% of the maximum rated output current.
(2)Turn output constant current adjustment trimmer I.ADJ counterclockwise until output voltage starts to fall.
Refer to
“
■
EVS600W Output Constant Current Set Point” on positions of output constant current adjust
trimmer.
Refer to
“
■
EVS600W Output Constant Current Set List” on constant current value.
(3)Increase load than output constant current set value and confirm output constant current value stays same
as set value. In addition, the output voltage decreases at constant current operation.
EVS600W Output Constant Current Set Point
The output current falls
The output current rises
when a trimmer is turned counterclockwise.
when a trimmer is turned clockwise.
EVS600W Output Constant Current Set List
Please set constant current value in the following range.
9/22
10.0
~
10.6A
5.3
~
9.7A
5.3
~
10.6A
Input Voltage condition
Classification
EVS3616R7
15.8
~
16.7A
8.35
~
15.3A
8.35
~
16.7A
100VAC
200VAC
EVS5710R6
200VAC
I.ADJ
H
I.ADJ
H
I.ADJ
H
Factory setting
Adjustable range