User manual
9-2
DSC/DSCT Series
SECT.
DESCRIPTION
FIELD
DEFAULT
Notes
P
58 Motor inductance in mH x rated motor current
20
÷
280
(DSC)
30
÷
450
(DSCT)
70
(DSC)
100
(DSCT)
r
P
60 External voltage reference corresponding to
the maximum motor speed (mV)
2500
÷
10000
10000
r
P
61 Encoder frequency reference coefficient
0
÷
16383
4096
P
80 TDE reserved parameter access key
0
÷
9999
-
n
P
81 Analogue ref. correction coefficient
50.0%
÷
199.0%
100.0%
t
P
83 Drive rated correction in % of the current limit
20.0%
÷
100.0%
50.0%
t
P
84 Drive limit reenter time constant
1.0
÷
10.0s.
2.5s.
t
P
85 VNS not stabilised voltage measurement coeff. 2500
÷
10000
4930
(DSC)
9015
(DSCT)
t
P
86 DC bus minimum voltage
180.0
÷
400.0V
220.0V
(DSC)
380.0V
(DSCT)
t
P
87 DC bus maximum voltage
200.0
÷
600.0V
410.0V
(DSC)
800.0V
(DSCT)
t
P
88 DAC_V coefficient for fs speed output
800
÷
1250
1000
t
P
89 Minimum flyback voltage (24V)
75.0%
÷
95.0%
85.0%
t
P
90 Maximum flyback voltage (24V)
100.0%
÷
120.0%
110.0%
t
P
91 Current reference offset
÷
100.0%
0
t
P
92 Current regulator delay compensation
0
÷
1000
÷
sec
200
t
P
99 Customer code number
0
÷
9999
95
t
On request, we can change the default value (95) of parameter
P99
, which sets the customer code number
(
P50
), to customise the drive.
Bold
P
indicates the most used parameters that had to be setted in a new installation.
9.2. CONNECTIONS
(Note: n = off-line , r = reserved to the customer, t = TDE-reserved)
CON.
DESCRIPTION
FIELD
DEFAULT
Notes
c
1 Logic input 1 meaning
1-8 (see sect. 7.1)
1 (
TQ.EN
)
r
c
2 Logic input 2 meaning
0 (see sect. 7.1)
0 (
DR.RUN
)
r
c
3 Logic input 3 meaning
1-8 (see sect. 7.1)
3 (
REF1EN
)
r
c
4 Logic input 4 meaning
1-8 (see sect. 7.1)
8 (
Fault Reset
)
r
c
5 Logic input 5 meaning
1-8 (see sect. 7.1)
2 (
EXT.EN
)
r
c
7 Logic output 1 meaning
0-9 (see sect. 7.2)
0 (
DR.READY
)
r
c
8 Logic output 2 meaning
0-9 (see sect. 7.2)
3 (
DR.ONLINE
)
r
c
9 Speed reference inversion
0 (not inverted) 1(inverted)
0
r
c
10 Simulated encoder channel B
inversion
0 (not inverted) 1(inverted)
0
r
c
11 Choice pulse/rev. resolver for
simulated encoder
0-7 (see sect. 7.4)
4 (512
PPR
)
r
c
12 Choice zero simulated encoder
phase
0-3 (see sect. 7.4)
0
r
c
13 Meaning programmable
analogue output
0-3 (see sect. 7.3)
1
c
14 Choice external reference
0 (analogue) 1 (frequency)
0
r
c
19 Exclusion alarms
A3,A4,A5,A9,A7
0-31 (see sect. 8.2)
0
r
c
20 Exclusion integral on speed
regulator
0 (not excluded) 1 (excluded)
0
n
c
21 Software on line
0(stop) 1(run)
1
c
22 Parallel bit to REF1
0(OFF) 1(ON)
0
c
23 Parallel bit to REF2
0(OFF) 1(ON)
0
c
24 Parallel bit to LS1
0(OPEN) 1(CLOSED)
1