User manual
3-8
DSC/DSCT Series
SAFETY ACTIVE
DESCRIPTION
REMEDIES
A12 Input
configuration
error
Two digital input were set
with the same function.
Check inputs configuration.
A13 pole setting error The drive has been set
with a wrong poles number
(P53, P54).
Check poles number.
A14 Mains
connections error
Motor phases U,V,W are
inverted.
Check the sequence of motor phases.