3. Intended use

Measurement of current in the specified measuring range for process signals

Indoor use non condensing, non corrosive.

Panel mounting.

In operation, supply the device preferably via screw terminals with 12 to 24 V
AC/DC. If the device is supplied via USB in operation, USB supply voltage must
be at least 5 V.

Failure to comply with these instructions will void all guarantee and warranty.

4. Description

The  measurement mode analogue  signal  0/4  to 20 mA  DC is  supported  at  two
measurement inputs. The multi display with RGB backlight is able to display up to
four   parameters   simultaneously.   Thresholds   can   be   associated   with   individual
warning colours. The unit can be switched between measurement modes via an
external switch. Minimum and maximum values are recorded and can be displayed
and reset via jumper or an external switch. Measured values are recorded over a
timespan of 36 seconds up to 14 days. The timebase as well as the display of the
measuring history can be activated by an external switch. The measured values
remain stored as long as the device is supplied with voltage.

The following parameters can be adjusted using the configuration software “Digalox
Manager”:   scale   endpoint,   scale   caption,   display   style   (pointer,   tachometer,   bar
graph,   and   more),   splash   image,   backlight   colour,   thresholds   for   alarm   output,
threshold   warning   colour   (light,   blink),   hysteresis,   and   more.   Recorded
measurement   values   can   be   read   and   a   continuous   transmission   of   the   actual
measuring value can be enabled. Using the software, values can be viewed and
exported as CSV. Depending on the model, measured values can be transmitted via
USB, XBEE radio technology or RS485 Modbus interface. In addition, the devices
feature   a   counting   function   with   data   retention.   This   enables   operating-hours-
counters or time-counters for exceeding and falling below threshold values.

Visit 

www.digalox.com

 to download the software “Digalox Manager”.

-----

 2 / 8 

-----

Summary of Contents for 103317

Page 1: ...t The device must not be used as the only protective device or protective shutdown The device is not intended to protect persons or facilities against harm Specific devices must be used to guarantee s...

Page 2: ...recorded over a timespan of 36 seconds up to 14 days The timebase as well as the display of the measuring history can be activated by an external switch The measured values remain stored as long as t...

Page 3: ...3 2 1 5 4 Back 1 2 optocoupler switch outputs 2 Jumper pins J1 J12 for activating switching of graphical historic data display min max display auto scaling measurement mode 3 Supply voltage input 4 In...

Page 4: ...sensor with voltage supply 20 mA analogue signal I2low I2high I1high I1low max 100 mA 0 mA 20 mA FF 100 mA 2 20 mA analogue signal max 100 mA 0 mA 20 mA FF 100 mA I2low I2high I1high I1low max 100 mA...

Page 5: ...t the Digalox Manager software and connect it to the device Settings can then be made on the various tabs and saved in the device Please note that the measurement mode selected in Digalox Manager is d...

Page 6: ...interval 2 sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next setting In order to save the setting perm...

Page 7: ...pdate 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 internal memory locations Alarm outputs 2 optocoupler outputs max 30 V DC 50 mA Permissible voltage between supply an...

Page 8: ...information TDE Instruments GmbH Gewerbestra e 8 D 71144 Steinenbronn Phone 49 7157 20801 E Mail info tde instruments de Internet www tde instruments de www digalox com 8 8 56 3 83 5 72 0 72 0 77 5 18...

Reviews: