background image

2800 Laura Lane • Madison, WI 53562  |  800.288.9383 • fax: 608.836.9044  |  www.tcsbasys.com  

2

3

Contents

CONTENTS

 & FEATURES

Factory IP Network Address 
Configuration

Description   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1
Features   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1
Factory IP Network Address Configuration

   .  .  .  .  .  .  .  .  .  .  .

 1 

Mounting .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Wiring   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
RS-485 Controller Network Wiring & Setup

 .  .  .  .  .  .  .  .  .  .  .  . 3

Gateway Configuration Page

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

5

Commissioning Tools

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

6

Programming - Lighting Module   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Programming - Pulse Meter   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
TCS ZigBee Wireless Network   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11
LED Display and Push Buttons .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11

Checkout & Troubleshooting

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11

UBIQUITY CLOUD SITE GATEWAY

• 

Enables controller interoperability with Ubiquity

• 

Enables Ubiquity to maintain controller programming 

and scheduling

• 

Compatible with all TCS Basys supported controllers

• 

Controller protocols supported: TCSbus, Modbus

• 

Supervisory control routines and override strategy

• 

Auto discovery of networked controllers

• 

Three (3) integrated RS-485 serial ports

• 

Additional serial ports can be added via USB ports

• 

Integrated Ethernet controller with firewall

• 

Integrated configuration web page

• 

User adjustable controller monitoring rate

• 

Remotely upgradable gateway software

ENERGY METER (SEQ100)

Utility Pulse Counting Meter for Monitoring of:

• 

Electric single and 3 phase kW and kWh

• 

Gas

• 

Water

• 

BT 

LIGHTING CONTROLLER (SLQ218)

• 

365-day programming for each circuit

• 

Analog input for photo sensor with the ability 

toprogrammingremotely adjust sensitivity level

• 

Analog input for photo sensor with the ability to 

remotely adjust sensitivity level

• 

Selectable power failure state

• 

Eight-channel lighting schedules for interior and 

exterior applications

• 

Digital photocell inputs

• 

Astronomical clock

QWL 3 .1 Rev 3 Series Panels are typically ordered pre-pro-

grammed to customer specific networks and no additional 

software configuration is required. This is the preferred 

purchasing method .
 

If a QWL 3 .1 Rev 3 Series Panel is purchased without 

pre-programming, it will be shipped with the DHCP client 

enabled. The configuration page is available through a 

browser for additional configuration of the QWL 3.1 Rev 3 

Series Panel at the local IP address . Contact your network 

administrator to determine the local IP address (refer to 

the MAC address available on the product label). 

Features

• 

External time clock or occupancy sensor input for each 

channel

• 

Channel status LEDs

• 

Selectable normally open or normally closed relays

• 

Built-in 2 Amp relays with hand/off/auto switches

Summary of Contents for QWL 3.1 Rev 3

Page 1: ...x 608 836 9044 www tcsbasys com Rev 0617 PRODUCT MANUAL The QWL 3 1 Rev 3 Integrated Building Manager Panel contains a Ubiquity Cloud Site Gateway w integrated lighting and energy management controls...

Page 2: ...METER SEQ100 Utility Pulse Counting Meter for Monitoring of Electric single and 3 phase kW and kWh Gas Water BT LIGHTING CONTROLLER SLQ218 365 day programming for each circuit Analog input for photo...

Page 3: ...y contact digital inputs and 4 pulse meter inputs POWERING THE QWL 3 1 REV 3 SERIES PANEL The QWL 3 1 Rev 3 Series Panel is powered from a 120VAC 60HZ to 12VDC power supply module includ ed The QWL 3...

Page 4: ...wire a 120 terminating resis tor across the A and B terminals at the QWL 3 1 Rev 3 Series Panel See 1 below If the QWL 3 1 Rev 3 Series Panel will be in the middle of the network do not wire in the te...

Page 5: ...ormation in this section click the Update Installation Info button RS 485 Network Port Configuration Configure each of the detected COM ports for this site Typically you will leave Auto Detection of C...

Page 6: ...ng Info button SECURITY INFORMATION This section contains settings which control the security of the gateway within the QWL 3 1 Rev 3 Series Panel and whether or not it can be accessed through the web...

Page 7: ...must be programed using TCS Insight or Ubiquity Cloud CHANNEL EVENT SCHEDULING There are eight independent channels each with its own schedule If the occupied or ON time for a particular day is from...

Page 8: ...ng channels Enable AI2 Threshold checkboxes and enter a threshold and a hysteresis to be used If AI1 is not used the channel power threshold MUST equal the scaling high limit Select whether you want t...

Page 9: ...cal time calculation Next select the channel s that should have the astronom ical time function and click the Enable box This is done in the Schedule section of the page Note For non North American Da...

Page 10: ...CT or on the utility output meter This value is only used for and electric meter P REV The Pulses per revolution for the meter This value is usually provided from the utility company CONSTANT The val...

Page 11: ...e to check and verify all wiring before powering up the QWL 3 1 Rev 3 Series Panel The QWL 3 1 Rev 3 Series Panel is designed to contain 24 VAC devices and wiring ONLY No line voltage 120 VAC or great...

Page 12: ...rify that the power supply nodule included with the QWL 3 1 Rev 3 Series Panel is plugged in to an outlet that has power IF THEN Check that the baud rate set on the controller s are all set the same V...

Reviews: