background image

 

3/2013 

TCS TürControlSysteme AG, TCS Hotline Germany:  +49 (0) 41 94 - 9 88 11 88 

Subject to technical changes. 

Fax: +49 (0) 41 94 - 9 88 129  

  E-Mail: 

[email protected]

 

PI_PAK_uk   1A 

win:clip

TM

 system 

 

The device is equipped with the win:clip system, thus opening and closing the station can 
be realised without screws. 

 

Open the housing 
1. 

Push the enclosed win:clip key into the small open-
ing within the loudspeaker cover. Press the key into 
the opening until stop and keep it in this position. 

2. 

Push the name plate glass slightly upwards until it 
jumps out. 

3. 

Remove out the glass. 

4. 

Remove the win:clip

TM

 key. 

 
 

 

Close the housing 
5. 

Push the enclosed win:clip key into the small open-
ing within the loudspeaker cover. Press the key into 
the opening until stop and keep it in this position. 

6. 

Push the name plate glass under the loudspeaker 
cover. 

7. 

Press the name plate glass onto the device. Push it 
slightly downwards until it snaps-in. 

8. 

Remove the win:clip

TM

 key.

 

 

 
 
 
 

Installation 

 

!

 

For a fully operational function of the microphone a distance of 

5cm

 below the device 

must be observed! 

 

 

1. 

Open the front-door station (see win:clip

TM

 system). 

2. 

Break through the foam cover at the backside of the device carefully and insert the lines 
through the cable gland. 

3. 

Install the front-door station at both attachment holes with suitable screws to the wall. 

 

!

 

Take care that the lines are not clamped under the spacer on the backside of the 
device. 

 
 

Summary of Contents for PAK

Page 1: ...lSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes Fax 49 0 41 94 9 88 129 E Mail hotline tcsag de PI_PAK_uk 1A Product information PAK Front door stations series for s...

Page 2: ...ring example 8 Connection diagram 8 Commissioning 8 Labelling the nameplates 9 Setting the volume of microphone and loudspeaker 9 Bell button programming 10 Basic principle 10 Programming a bell butto...

Page 3: ...E 0100 must be observed When installing TCS BUS systems the general safety regulations for telecommunication systems according to VDE 0800 must be observed Inter alia separated conduit of heavy curren...

Page 4: ...W x D 153 to 241 x 104 x 16 mm weight 335 g PAK01 to 600 g PAK08 acceptable ambient temperature 20 C to 50 C input current 3 wire technique I a 0 4 mA I P 10 6 mA max input current 3 wire technique I...

Page 5: ...be allocated with two indoor stations long life and energy saving name and information plate illumination shatter proof name plate glass acknowledgement tone when pressing the bell button communicatio...

Page 6: ...ousing 5 Push the enclosed win clip key into the small open ing within the loudspeaker cover Press the key into the opening until stop and keep it in this position 6 Push the name plate glass under th...

Page 7: ...amaging the device Please observe that no line will be clamped below the spacer at the backside of the front door station Connectiong 1 Strip the cable ends 2 Connect the lines depending on the type o...

Page 8: ...Subject to technical changes Fax 49 0 41 94 9 88 129 E Mail hotline tcsag de PI_PAK_uk 1A Wiring example Connection diagram Commissioning Install the devices of the system completely Check the a b an...

Page 9: ...he scope of delivery to open the gabs The inserted in name tags stand 2 mm above the gab and can be easily pulled out upwards We recommend printing the name tags on a resistant special foil The foils...

Page 10: ...rial number condition ex works allocation de leted this button can be used to switch lights Programming a bell button Make sure that the indoor station is connected to the TCS BUS and the mains voltag...

Page 11: ...front door and indoor station1 2b Alternative programming via floor push button if the indoor station is not accessible Press floor push button 2 times in quick succession each time a ring tone sound...

Page 12: ...configo Note Repeated programming of an already programmed bell button always changes only the second seri al number If you want to change the serial number programmed first you have to delete both s...

Page 13: ...or the configuration software configo Delete the programming Before an already programmed bell button can be reprogrammed the previous program ming must be deleted 1 Initiate Power supply and control...

Page 14: ...d connect one side to ground b wire at the power supply Optional strand or star formed wiring Table loop resistances cable length in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2...

Page 15: ...be removed from the programmed front door station and inserted into a new identical constructed front door station Before replacing the EEPROM switch OFF the supply voltages Open the housing respectiv...

Page 16: ...onic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electricians Please note our c...

Reviews: