Programming a second indoor station at a bell button (parallel call)
The parallel call is calling 2 indoor stations from the bell button of the front-door station.
The floor push button is only calling the permanently wired indoor station.
If bell button and floor push button are to have the same functionality, the function parallel
allocation must be used. Thus several indoor stations are reacting on the same bell button
as well as on the same floor push button. The parallel allocation has to be adjusted with
the Service Device TCSK-01 or the configuration software configo
™.
Note
: Repeated programming of an already programmed bell button always changes only the second seri-
al number. If you want to change the serial number programmed first, you have to delete both serial num-
bers and reprogram the device again.
1
Initiate
Power supply and control unit
press shortly
LED blinks
Programming mode of the system is ON
2a
Programming via voice connection
oder
◄6s►
◄6s►
establish voice connec-
tion to the front-
door station
press button until a Prog2
tone and a NoProg tone and
...
... a ring tone at the front-
door and indoor station
sounds
1)
release
2b
Alternative:
Programming via floor push button
(if the indoor station is not accessible)
+
◄6s►
◄6s►
press floor push button
for 2 times in quick
succession, each time
a ring tone sounds
press button until a Prog2
tone and a NoProg tone and
...
... a ring tone at the front-
door station and indoor
station sounds
1))
release