Settings
Pre-settings ex works
group membership (3 groups)
all 63
serial numbers of up to 5 radio senders
All not assigned
audio AS-border
0 (no call distinction)
ring tones
different for door call, internal call, floor
call
function floor push button
(floor call / control function 8)
floor call
volume control
OFF (always max. volume)
floor push button as opener / closing contact
opener
optical and acoustic error indication (ON/OFF) OFF
Pre-set times
communication time
max. 2 min
call standby time
2 min, if the device is calling
30 s, if the device is called
timeout group call
2 min
timeout announcement (group and single)
internal standby time, if the device is calling or
is called
around
30 sec
Set up microphone sensitivity
Can be continuously adjusted at the control
microphone sensitivity.
This setting influences only the sensitivity of the
microphone when listen-in into rooms.
Note: During hands-free talking, the microphone sensitivity
does not change.