15
4
Power supply and control unit: switch off the programming mode of the system
Shortly press the
RUN/PROG button.
The LED is on.
The programming mode of the system is
switched OFF.
e)
a)
Do not press the RUN/PROG button longer than 5 seconds. Otherwise you will activate the light switch function of the front door station. The
bell button cannot be programmed. The LED blinks. Shortly press the RUN/PROG button to switch off the programming mode. Shortly press
the RUN/PROG button to switch on the programming mode. Program the bell button.
If the light switch function is activated, you can switch the lights by pressing the door release button of the indoor station, if no voice communi-
cation is established. Switch on the programming mode. Press the RUN/PROG button longer than 5 seconds until the LED lights up. The light
switch function is deactivated.
b)
Not necessary, if the bell buttons have not been programmed, see product information of the front door station.
c)
If there sounds a Progsperr tone (long high tone followed by long low tone) instead, the front door station is equipped with a programming
lock. You can deactivate the programming lock only with the service device TCSK or the configuration software configo™.
d)
An acknowledgement tone sounds at front door stations (as of 2009) if the serial number of the indoor station was received (see product
information of the front door station).
e)
device specific indication modes of the front door station see product information of the font-door station
Cleaning
CAUTION!
Loss of function due to short-circuit and corrosion.
Water and cleaning agents can enter the device. Electronic elements can get damaged due to
short-circuit or corrosion.
Avoid water and detergents from entering the device! Clean the device
with a dry or slightly wet
cloth.
CAUTION!
Damages on the surface of the device
Abrasive or scratching detergents damage the surface of the device.
Do not use any abrasive detergents! Remove strongerstains with a pH neutral household
cleaner.
Conformity
Declarations of conformity are available for download under www.tcsag.de.