background image

 

 

 

15 

Power supply and control unit: switch off the programming mode of the system 

 

 

 
 
 
 

 

Shortly press the 
RUN/PROG button. 

The LED is on. 

 

The programming mode of the system is 
switched OFF. 

e)

 

 

 

a)

 

Do not press the RUN/PROG button longer than 5 seconds. Otherwise you will activate the light switch function of the front door station. The 
bell button cannot be programmed. The LED blinks. Shortly press the RUN/PROG button to switch off the programming mode. Shortly press 
the RUN/PROG button to switch on the programming mode. Program the bell button. 
If the light switch function is activated, you can switch the lights by pressing the door release button of the indoor station, if no voice communi-
cation is established. Switch on the programming mode. Press the RUN/PROG button longer than 5 seconds until the LED lights up. The light 
switch function is deactivated.  

b)

 

Not necessary, if the bell buttons have not been programmed, see product information of the front door station. 

c)

 

If there sounds a Progsperr tone (long high tone followed by long low tone) instead, the front door station is equipped with a programming 
lock. You can deactivate the programming lock only with the service device TCSK or the configuration software configo™. 

d)

 

An acknowledgement tone sounds at front door stations (as of 2009)  if the serial number of the indoor station was received (see product 
information of the front door station). 

e)

 

device specific indication modes of the front door station see product information of the font-door station 

 
 
 
 
 

Cleaning 

 

CAUTION! 

Loss of function due to short-circuit and corrosion. 

Water and cleaning agents can enter the device. Electronic elements can get damaged due to 
short-circuit or corrosion. 
Avoid water and detergents from entering the device! Clean the device

 

with a dry or slightly wet 

cloth. 

 

 

CAUTION! 

Damages on the surface of the device 

Abrasive or scratching detergents damage the surface of the device. 
Do not use any abrasive detergents! Remove strongerstains with a pH neutral household 
cleaner. 

 
 
 
 

Conformity  

 

Declarations of conformity are available for download under www.tcsag.de. 

 
 
 

Summary of Contents for ASX1300 -0010 Series

Page 1: ...Product information Audio front door station series ASX1300x 0010 for surface mount...

Page 2: ...2...

Page 3: ...ns 5 requirements to protect against lightning 5 Product description 6 Intended use 6 Short description 6 Device overview 7 Technical data 7 Mounting and installation 8 Installation 8 Connecting the l...

Page 4: ...em manual available in the download area at www tcsag de Used symbols and warning notices Symbol signal word Explanation DANGER The signal word describes an endangering with a high level of risk Failu...

Page 5: ...sys tems according to VDE 0800 must be observed Inter alia separated cable routing of high and low voltage lines minimum distance of 10 cm in case of a common cable routing use of separators between h...

Page 6: ...bell push button 2 indoor stations can be allocated durable and energy saving nameplate illumination shatter proof nameplate glass acknowledgement tone when pressing the bell button conversation time...

Page 7: ...rophone 12 bell button with labelling Technical data supply voltage 24 V 8 power supply and control unit input current in resting position 3 wire operation I a 0 4 mA I P 9 13 mA maximum input current...

Page 8: ...it to ensure a proper func tion of the microphone Fig 1 Mounting height Opening the device The upper part of the housing is screwed together with the rear panel via a hexagon socket screw Fig 2 Loosen...

Page 9: ...l do not get clamped Fig 3 Assembling the rear panel Connecting the lines Strip the lines Connect the lines a b and P according to the labelling 1 Fig 4 Observe the example circuit on page 12 2 wire t...

Page 10: ...iate socket Fig 6 Put on the upper part of the housing 2 onto the rear panel Fig 7 Turn down the upper part of the housing onto the rear panel 3 Fix the upper part of the housing to the rear panel wit...

Page 11: ...es made of paper We recommend to print out the nameplates on a durable special foil made of plastics You can order replacement foils directly under E Mail info tcsag de or use our labelling service ww...

Page 12: ...12 Example circuit Fig 10 Circuit diagram For further information see TCS system manual The TCS system manual can be downloaded at www tcsag de...

Page 13: ...ex works A change is not always required Adjust the loudspeaker volume Turn the control 1 right to increase the volume of the loud speaker Fig 11 Turn the control 1 left to reduce the volume of the l...

Page 14: ...ramming lock is activated you cannot program any bell button To deactivate the programming lock you need a Service Device TCSK or the configuration software configo 1 Power supply and control unit swi...

Page 15: ...on c IftheresoundsaProgsperrtone longhightonefollowedbylonglowtone instead thefrontdoorstationisequippedwithaprogramming lock YoucandeactivatetheprogramminglockonlywiththeservicedeviceTCSKortheconfigu...

Page 16: ...Our standard terms and conditions of sale you ll find under www tcsag de Spare parts accessory Short text Article number laser film foil matt format DIN A4 nameplates 0001060 special wrench 0012493 w...

Reviews: