Short description 

Basic functions 

ringing 
 
 
 
 
 

Pressing the connected bell button, provided by 
customer 

  triggers ringing at the indoor station, a tone at the 

ASI11000 sounds, 

  triggers the light switch function in the power 

supply and control unit, an acknowledgement tone 
sounds. 

number of bell 
buttons 

32 bell buttons can be connected directly  
(8 x 4 button matrix) 

serial number per 
bell button 

max. 2 possible 

storage of the bell 
button assignment 

The assignment is stored only in the EEPROM of the 
connected ASI11000.  

 

Summary of Contents for ASI11000

Page 1: ...Product information Built in door loudspeaker ASI11000 0000 Built in bell button extension ASI21000 0000...

Page 2: ...2...

Page 3: ...eaker ASI11000 0000 13 Device overview 14 Technical data 15 Intended use 16 Short description 17 Basic functions 17 Additional functions 18 Assembly 20 Installation position 20 Fixing the housing 20 F...

Page 4: ...operation 28 Wiring diagram 2 wire operation 29 Connection diagram 30 Connection lines 30 Commissioning 31 Customising for long lines 31 Error detection and indication 32 Settings 33 Factory settings...

Page 5: ...ion on full duplex operation 49 Programming with the Service Device TCSK 01 51 Programming with the device configurator configoTM 52 Repairs 52 Notes 53 Data transfer from another ASI11000 54 Transfer...

Page 6: ...screws 71 Fixing by glue 72 Dimensional drawing 73 Installation 74 Connect the bell buttons provided by customer 74 Connecting diagram 74 Notes 75 Coupling of ASI11000 and ASI21000 75 Coupling of ASI...

Page 7: ...d handle 1 x screw 3 x 25 e g for Renz Adapter Antivandalism 3 x screw 3 x 10 e g for Renz Adapter Standard Antivandalism product information ASI21000 1 x built in bell button extension ASI21000 0000...

Page 8: ...ing TCS BUS systems the general safety regulations for tele communication systems according to VDE 0800 must be observed separated conduit of heavy current and low current lines minimum distance of 10...

Page 9: ...ightning it has to be ensured that a voltage of each 32 V DC is not to be exceeded at the TCS BUS wires General information on the conduit in TCS audio systems The conduit is determined by structural...

Page 10: ...x permitted loop resistance the cross section of the wire can be doubled that means for one wire two lines are used illustra tion The lines must be twisted When using shielded lines connect the shield...

Page 11: ...in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55 1 43 30 3 83 2 14 40 5 10 2 86 50 6 38 3 57 60 7 65 4 29 70 8 93 5 00 80 10 20 5 71 90 11 48 6 43 100 12 76 7 14 150 19 13 10...

Page 12: ...Hz of the VS Install a b short circuit at the VS Other devices are not disturbing the measurement can stay connected Measure the resistance at a b at the last IS or AS 20 Ohm max 160 m distance AS IS...

Page 13: ...13 Built in door loudspeaker ASI11000 0000...

Page 14: ...n for bell button extension service opening with rubber cap microphone can be separated TCS BUS connection mounting strap 5 x attachment hole connection for bell buttons space for microphone cable sym...

Page 15: ...r area behind front panels provided by customer input current I a 0 1 mA I P 4 4 mA max input current I Pmax 140 mA length microphone cable mm 250 3 wire technique necessary In 2 wire technique one AS...

Page 16: ...tdoor area The combination of ASI11000 and TCKE as well as the combination of TCU2 and ASI21000 is not possible The operation of the built in door loudspeaker ASI11000 is only per mitted with closed s...

Page 17: ...n the power supply and control unit an acknowledgement tone sounds voice connection to the indoor station voice controlled hands free talking standard manually controlled simplex communication can be...

Page 18: ...tored allocations do not get lost in case of a voltage breakdown Additional functions connection for bell button extension ASI21000 pluggable via a connector max 6 ASI21000 can be connected that corre...

Page 19: ...e manually can be adjusted separately for loudspeaker and acknowledgement tones 2nd slot to read in TCU2 memories to read in TCKE memories configurable functions for bell buttons provided by customer...

Page 20: ...flush on the front panel provided by customer Thus the sound from the loudspeaker is lead directly to the micro phone and not through an air gap between housing and installation site otherwise the sou...

Page 21: ...e The area on which the door loudspeaker is to be glued has to be smooth and free from dust and grease Pull the protective foil off the rubber plate and stick the device to the backside of the front p...

Page 22: ...connection cable from the microphone cable chamber Ensure that the cable is not pulled off at the microphone For the installation behind a loud speaker cover the attachment hole for the sound penetra...

Page 23: ...23 Dimensional drawing height 34 mm...

Page 24: ...z adapter Standard To install the ASI11000 via Renz adapter adapter for loudspeaker cover with con nection port article no 97982195 the 3 attachment holes have to be used as shown in the illustration...

Page 25: ...er Antivandalism to install the ASI11000 via Renz adapter adapter for loudspeaker cover RSA loose article no 97982164 the 2 attachment holes have to be used as shown in the illustration 2 screws enclo...

Page 26: ...ovided by customer For the installation in the protected outdoor area avoid water from entering the device with suitable measures Only use the enclosed small screwdriver to connect the lines and to av...

Page 27: ...wire technique the connection of a FAA1100 is not permitted When removing a TCU2 GH Mind the corresponding terminals TCU2 GH 5 6 7 8 ASI11000 E F G H Connect buttons from a different systems e g eleva...

Page 28: ...or stations depends on the type see product infor mation of the indoor station Attention when using a FAA1100 the door release time of the power supply and control unit must be set to maximum 1 2 1 2...

Page 29: ...can be realised depends on the type of indoor stations For detailed information see the product information of the indoor station Connecting a FAA1100 is not permitted Max one ASI11000 at the BVS20 T...

Page 30: ...82 mm2 0 32 1 0 mm Max number of wires per terminal contact connection bell buttons each 2 x 0 8 mm connection TCS BUS 3 x 0 6 mm or 2 x 0 8 mm Further wires must be connected via auxiliary terminals...

Page 31: ...Check the a b and P wire against each other for short circuits Switch on the mains voltage Customising for long lines The front door station ASI11000 can be configured for long lines with a loop resis...

Page 32: ...z Insert the EEPROM switch on the mains voltage again a and P wire are interchanged or short circuited Exchange the a and P wire or eliminate the short circuit device is in stand by mode again a wire...

Page 33: ...s door release time 3 s The times can be adjusted with the Service Device and the configurator configoTM Removing and adding an ASI21000 in one system Only the last bell button extension ASI21000 at t...

Page 34: ...for the setting Open the rubber cover of the ser vice opening The volume for language loud speaker and acknowledgement tones can be set via two separate controllers The controllers are set to an aver...

Page 35: ...tation Per bell button 1 or 2 indoor stations serial numbers can be allocated and called When no serial number is allocated to a button delivery state or delet ed by pressing this button the lights ca...

Page 36: ...ing the reprogramming of the bell buttons Legend Shortly press the button Shortly press the button until Release the button Ring tone Positive acknowledgement Deletion tone sequence LED blinks slowly...

Page 37: ...nitiate Switch on the programming mode of the system Power supply and control unit ASI11000 RUN PROG button shortly press LED blinks Green operation LED blinks Programming mode of the system is switch...

Page 38: ...press the bell button a ring tone sounds at the front door and indoor station 1 Repeat the steps until all bell buttons are programmed 1 If there sounds a Progsperr tone instead the programming lock...

Page 39: ...is not available Shortly press the floor push button two times each time a ring tone sounds Positive acknow ledgement sounds Press a bell button a ring tone sounds at the front door and indoor statio...

Page 40: ...ights up Green operation LED is on Programming mode of the system is switched off 1 If there sounds a Progsperr tone instead the programming lock is activated at the front door station The programming...

Page 41: ...and floor push button should have the same functionality only the function parallel allocation can be used Thus only one serial number is allocated to the bell button the allocation of further indoor...

Page 42: ...nitiate Switch on the programming mode of the system Power supply and control unit ASI11000 RUN PROG button Shortly press LED blinks Green operation LED blinks Programming mode of the system is switch...

Page 43: ...the front door station Positive acknow ledgement tone sounds Press the bell button until Prog2 tone and a NoProg tone and a ring tone at the front door station and a ring tone at the indoor station s...

Page 44: ...loor push button 2 times each time a ring tones sounds Positive acknow ledge ment tone sounds Press the bell button until Prog2 tone and a NoProg tone and a ring tone at the front door station and a r...

Page 45: ...ss LED lights up Green operation LED lights up Programming mode of the system is switched off 1 If there sounds a Progsperr tone instead the programming at the front door station is activated The prog...

Page 46: ...can be programmed anew the programming must be deleted 1 Initiate Switch on the programming mode of the system Power supply and control unit ASI11000 RUN PROG button shortly press LED blinks Green ope...

Page 47: ...47 2 Delete a button Press the button until as the deletion tone sequence sounds 1 Release...

Page 48: ...ED lights up Green operation LED lights up The programming mode of the system is switched off 1 If there sounds a Progsperr tone instead the programming lock at the front door station is activated The...

Page 49: ...e door or send control function with bell button provided by customer A button which is not allocated to a resident can be used to open a door or to send a control function Connect the bell button pro...

Page 50: ...ipants can speak simultaneously without reducing the volume of one participant such as in case of voice controlled hands free talking Please observe In full duplex operation feedback effects are possi...

Page 51: ...wing parameter can be set with the Service Device AS address communication time programming lock type of acknowledgement tone speaking only in case of active door stand by light switch function via do...

Page 52: ...sing a bell button serial number of the control function serial number of the ASI11000 all functions of the TCSK 01 bell button programming set the door stand by time sending a 16 bit door release com...

Page 53: ...g mode of the system at the power supply and control unit is switched on or the green LED flashes error indication ATTENTION Remove and plug on an EEPROM always in voltage free condition programming b...

Page 54: ...off the mains voltage of the system Uninstall the defect ASI11000 install the new ASI11000 and connect it Remove the EEPROM from the defect ASI11000 Plug the EEPROM in the new ASI11000 on the ASI11000...

Page 55: ...5 All programmings are available again Intended operation only with all covers TIP Label the removed EEPROM immediately after the removal Thus the allocation of the data to the correct exchange device...

Page 56: ...e mains voltage of the system Uninstall the defect TCU2 install the ASI11000 and connect it Remove the EEPROM from the defect TCU2 Plug the EEPROM in the ASI11000 on the provided slot structural eleme...

Page 57: ...n was successful Switch off the mains voltage of the system Remove the EEPROM of the defect TCU2 from its slot Switch on the mains voltage and eventually evaluate the error indication Error indication...

Page 58: ...21000 is not possible Switch off the mains voltage of the system Remove the defect TCKE and the TCU2 install the ASI11000 and ASI21000 and connect them Remove the EEPROM from the defect TCKE Plug the...

Page 59: ...ready for transfer LED green ON LED red OFF or error indication Eliminate the error Note To transfer the EEPROM content of the TCU2 which needs to be exchanged too see data transfer from a TCU2 EEPRO...

Page 60: ...EEPROM found read in was successful Switch off the mains voltage of the system Remove the EEPROM of the defect TCKE from its slot Switch on the mains voltage and eventually evaluate the error indicat...

Page 61: ...ctivated at the power supply and control unit Only switch on the exchange mode by pressing the internal programming button of the device The red LED blinks TIP Always exchange only one indoor station...

Page 62: ...ually evaluate the error indication ASI1100 ready for the transfer LED green ON LED red OFF or error indication Eliminate the error Switch on the exchange mode Press the programming button for around...

Page 63: ...he replaced indoor station A ring tone sounds Switch off the exchange mode Shortly press the programming button The programming LED expires Negative acknowledgement tone new indoor station not found C...

Page 64: ...64...

Page 65: ...65 Built in bell button extension ASI21000 0000...

Page 66: ...erminal cover mounting strap 4 x connection bell buttons pluggable symbol installation position 1 symbol installa tion position 2 drilling pattern connection cable for ASI11000 ASI21000 program ming b...

Page 67: ...ing plastics black dimensions in mm H 56 x W 88 x D 30 weight 55 g acceptable operation temp 25 C 55 C according to DIN EN 50486 installation in the protected outdoor area e g behind loudspeaker cover...

Page 68: ...ion in letterbox systems or behind individual loudspeaker covers The extension corresponds to the built in door loudspeaker ASI11000 The ASI21000 can be used indoors as well as in the protected outdoo...

Page 69: ...SI11000 sounds triggers the light switch function in the power supply and control unit an acknowledgement tone sounds number of bell buttons 32 bell buttons can be connected directly 8 x 4 button matr...

Page 70: ...11000 possible corresponds to192 further bell buttons functions that can be configured functions for bell buttons provided by customer sending any control function when pressing a bell button serial n...

Page 71: ...lation position 2 microphone down wards See Device overview Fixing the housing The rubber plate of the ASI21000 housing should be flush with the loud speaker cover provided by customer Fixing with scr...

Page 72: ...by glue The surface on which the bell button extension is to be glued must be free from dust and grease Remove the protective foil from the rubber plate and glue the device on the backside of the fro...

Page 73: ...73 Dimensional drawing height 30 mm...

Page 74: ...ing in the protected outdoor area avoid water from enter ing the device with suitable measures Only use the enclosed small screwdriver to connect the lines and to avoid damaging the device The connect...

Page 75: ...r The buttons must be potential free Eventually a relay for decoupling must be interconnected to establish the potential free buttons Coupling of ASI11000 and ASI21000 The coupling of the ASI21000 wit...

Page 76: ...con nection cable Plug the connector of the cable on the connection of the prior ASI21000 Commissioning Install the devices of the system in voltage free state Switch on the mains voltage of the syst...

Page 77: ...er www tcsag de Downloads trade information Information on disposal The adjoining symbol shows that the device has to be disposed separately from domestic waste The materials used are recyclable Pleas...

Page 78: ...d processing in case of warranty for electricians Please note our conditions of sale and delivery available under www tcsag de Downloads trade information and included in our cur rent product catalogu...

Page 79: ...79...

Page 80: ...quarters TCS T rControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Fon 49 0 3933 879910 Fax 49 0 3933 879911 Mail info tcsag de www tcsag de TCS Hotline Germany Fon 49 0 4194 9881188 Fax 49 0 41...

Reviews: