10
Observe when selecting the cable
length: the loop resistance must not
exceed 20
Ω (table).
To keep the max. permitted loop
resistance, the cross-section of the
wire can be doubled, that means, for
one wire two lines are used (illustra-
tion). The lines must be twisted.
When using shielded lines: connect
the shields with each other and
earth one side (b-wire) at the power
supply.
Optional strand or star formed wir-
ing.