3-wire technique necessary!
In 2-wire technique one ASI11000, one BVS20 and a suitable number of
indoor stations are permitted (max. 16). The number of indoor stations
that can be realised depends on the type of the indoor station. For de-
tailed information see the product information of the indoor station!
In 2-wire technique, the connection of a FAA1100 is not permitted!
When removing a TCU2-GH: Mind the corresponding terminals!
TCU2-GH:
5
6
7
8
ASI11000:
E
F
G
H
Connect buttons from a different systems (e.g. elevator):
the buttons have to be potential-free. To establish potential-free buttons,
eventually a relay for decoupling must be interconnected.
Connect other consumers:
!
At the ASI11000
no
further consumer such as spots,
incandescent lamps or anything similar can be connected!
In this case, a separated transformer is necessary.