Short description
Display module for front-door stations in individualised assembly
for up to 1000 flats
LC display, 160 x 160 pixel with white-blue backlight
code lock function (number of codes: 3)
call destination selection via an alphabetically sorted resident list or by entering the tar-
get number (flat number) as quick selection
adjustable (rotation) direction in the name list, name list as of 6 data sets endless
name pre-selection can be realised via the initial letter
start screen can be configured by a qualified electrician
multi-lingual user guidance (can be programmed during the installation: German,
English, French, Danish, Dutch, Turkish, Serbian, Italian, Spanish, Portuguese,
Swedish, Slovak, Slovene, Czeck)
indication of date and time
automatic switch-over between summer and winter time
optionally outdoor temperature indication (temperature sensor FBS2100-0600 not in-
cluded in the delivery, see Accessory, page 18)
import function for old databases of predecessors
acknowledgement tone when pressing the bell button
acknowledgement tone for the start of the voice connection
output of voice messages for user guidance
communication time ex works: 56 seconds / can be adjusted with PS/2 kexpad (not in-
cluded in the delivery, see
, page 18) or ADx configurator (part of the mainte-
nance package FBI1210-0; not included in the delivery, see Accessory, page 18)
S-terminal to trigger door release, light switch, control or door call function (max. length
of the entrance connection line: 2 m)
R-terminal to connect an extended function
– door release
per resident dataset, 2 serial numbers can be stored
can be adjusted with PS/2 keypad or ADx configurator:
door release time at R-terminal ex works: 3 seconds /
door release in door standby time /
door standby time (to control the short-term memory in indoor stations) ex works: 56
seconds /
voice connection in door standby time /
resident dataset and parameter
!
Attention when using the display module
!
The display module is permitted exclusively for safety extra low voltage (SELV) and
protective extra low voltage (PELV).
Avoid direct solar radiation (ambient temperature max. +50 °C)!
Direct solar radiation reduces the durability of the liquid crystals in the display.