... by entering the flat number 

 

Display 

 

keypad module AMI10300 

 

Enter the flat 
number  
 
 

 

 

 

If the flat number of the resident is known, it can be en-
tered directly. 

 

 Enter the flat number (digits 0 till 9). 

 Confirm the entry with the 

OK button

 

Call a resident 
 
 
 

 

 

 

 

 

 Press the 

bell button

Confirming of the entered number by the display: 
A door call sounds at the front-door station. 

 
 
 
 
 
 
 

If the telephone does not respond resp. the front-door 
station receives no acknowledgement, the following note 
appears: 

 

Voice connection 

 

Establish the 
voice connec-
tion  
 

 

 

 

After accepting the door call at the called indoor station, a 
voice connection is established. 

 

It is displayed: 

 
End the voice 
connection  
 

 

17:19 

15,6°C 

Adler-Apotheke 

Arnold 

Baumgarten, E. 

Dombrowski, Alf 

Frey 

Rufen 

 

 

By putting down the handset at the indoor station or after 
the adjusted period of communication time is over, the 
voice connection is terminated. 

 

The resident list is displayed again.

 

Summary of Contents for AMI Series

Page 1: ...roduct information Series AMI Front door stations with display module AMI10105 AMI10200 AMI10300 AMI10400 Note on the validity of this product information This product information states specific information on the modules It is only valid in combination with the enclosed product information Modules of the series AMI in front door stations ...

Page 2: ... modules within the front door station 9 placement example for keypad module 9 placement example for jogwheel module 9 Wiring example 10 Connection diagram 10 Commissioning 11 Note on connecting the PS 2 keypad to the display module 11 Commissioning of a front door station with display module 11 Configuration 12 Factory settings 12 Configuration options 12 Display module AMI1010x 12 Settings 12 Op...

Page 3: ...m allen key 2 5 mm screwdriver with round handle programming manual Functional group with display module AMI1010x product information Modules of the series AMI in front door sta tions product information Functional group with display module Display module and loudspeaker module are delivered together as module combination LCD display and loudspeaker module AMI10105 0757 or AMI10105 0710 To set and...

Page 4: ...module combination LCD display and loudspeaker module and keypad or jogwheel module Loudspeaker module AMI10200 Overview 1 microphone 2 cover PS 2 socket Loosen the cover with allen key of 3 mm not included in the delivery Connect PS 2 keypad 3 connection cable micropho ne 4 connection cable PS 2 key pad jogwheel module 5 connection cable loudspea ker Technical data housing aluminium anodised H x ...

Page 5: ...485 10 RS485 11 USB Typ B 1 1 2 0 Technical data display 160 x 160 pixel white blue module plate glass inserts housing display unit aluminium anodised polycarbonate PC AR steel zink coated H x W x D 131 x 111 x 45 mm weight 560 g acceptable ambient temperature 20 C to 50 C input current standby max input current I a 0 4 mA I P 140 mA I Pmax 245 mA RS485 interface matching resistor transmission 120...

Page 6: ...port function for old databases of predecessors acknowledgement tone when pressing the bell button acknowledgement tone for the start of the voice connection output of voice messages for user guidance communication time ex works 56 seconds can be adjusted with PS 2 kexpad not in cluded in the delivery see Accessory page 18 or ADx configurator part of the mainte nance package FBI1210 0 not included...

Page 7: ...button Confirm the entry the menu request 6 C button Code lock function Enter the access code 7 jogwheel Selection help menu resident list Turn to get into the help menu turn further to get to the resident list 8 connection cable keypad mod ule 9 PS 2 connection IN loud speaker jogwheel module 10 PS 2 connection MAIN display jogwheel module Technical data keypad module jogwheel module housing alum...

Page 8: ... key 2 5 mm Pull off the display unit from the module plate 2 Install the module plate and display unit in the front panel Put the module plate 2 onto the front panel 3 and fix it with the enclosed 4 x fastening nuts M4 4 Note The sealing strip 5 which sticks to the module plate must face upwards Put the display unit onto the module plate and fix it with the 4 x panhead screws 1 Note The orientati...

Page 9: ...have to be wired placement example for keypad module placement example for jogwheel module 1 connection cable loudspeaker module microphone 1 connection cable loudspeaker module microphone 2 connection cable loudspeaker module loudspeaker 2 connection cable loudspeaker module loudspeaker 3 connection cable keypad display module 3 PS 2 connection cable jogwheel loudspeaker module 4 PS 2 connection ...

Page 10: ...4 9 88 129 PI_AMI_FG DISPLAY uk 2A Wiring example Connection diagram Note on the FBS2100 Optionally available the temperature sensor to indicate the temperature in the display not included in the delivery see Accessory page 18 ISH3030 ISH3030 front door station floor push button floor push button Front door station ...

Page 11: ...lay module device start After switching ON the system screen appears for 5 seconds The resident list appears 30 s after switching on the device the start screen appears ex works with TCS logo The device is in standby mode Start screen to customer requirements Another logo or image can be configured as start screen see enclosed programming manu al Functional groups with display module AMI1010x Uplo...

Page 12: ... jogwheel module AMI10400 was selected the display module must be configured anew with the software ADx configurator or PS 2 keypad see any pro gramming manual Functional group with display module AMI1010x Settings For setting and programming the display module you need exclusively a PS 2 keypad not included in the delivery see Accessory page 18 Using a PC keypad with USB connection or a USB adapt...

Page 13: ...tter appears Confirm the selected name with OK button Browse Press the UP or DOWN button until the required name is highlighted Turn the jogwheel care fully to get to the help menu or press the ABC button A list with the first initials of the resident names is displayed Browse Turn the jogwheel until the required initial letter appears Confirm the selection with the ABC button The first resident w...

Page 14: ...lection in the resident list start select a name browse in the resident list 17 19 15 6 C Adler Apotheke Arnold Baumgarten E Dombrowski Alf Frey Rufen Press the UP or DOWN button two times The resident list is dis played Browse Press the UP or DOWN button until the required name is highlighted Turn the jogwheel care fully to get to the help menu or Browse Turn the jogwheel until the required name ...

Page 15: ...he entered number by the display A door call sounds at the front door station If the telephone does not respond resp the front door station receives no acknowledgement the following note appears Voice connection Establish the voice connec tion After accepting the door call at the called indoor station a voice connection is established It is displayed End the voice connection 17 19 15 6 C Adler Apo...

Page 16: ...sons The enter menu can only be called up from the start screen display keypad module AMI10300 Enter the ac cess code Entry correct Unknown access code Press the C button The following is displayed Enter the code with 1 to 4 digits Confirm the entry with the OK button A positive acknowledgement tone beep or voice out put sounds The door opener is triggered A negative acknowledgement tone 3 times b...

Page 17: ...ont door sta tion 1 Eventually save the data of the display Various Save storage 2 Open the housing 3 Disconnect the display from the power supply pull off the connection socket 4 The EEPROM storage is located in the elctronic part corresponding to the display module Pull off the EEPROM storage 5 Plug the EEPROM storage into the new unprogrammed display module on the pins Observe the orientation o...

Page 18: ... Article number Temperature sensor flush mount single FBS2100 0600 PS 2 keypad German for display module AMI1010x 0008737 Maintenance package FBI1210 0 Display module LCD graphic 1000 flats anodised black AMI10105 0000 Loudspeaker module anodised black AMI10200 0057 Display module LCD graphic 1000 flats anodised silver AMI10105 0010 Loudspeaker module anodised silver AMI10200 0010 ...

Page 19: ...05 2013 19 TCS TürControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes Fax 49 0 41 94 9 88 129 PI_AMI_FG DISPLAY uk 2A Notes ...

Page 20: ...ical changes Fax 49 0 41 94 9 88 129 PI_AMI_FG DISPLAY uk 2A Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS TürControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Phone 49 0 39 33 87 99 10 Fax 49 0 39 33 87 99 11 E Mail info tcsag de www tcsag de ...

Reviews: